verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um

The AirTAC GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$137.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um

The AirTAC GC400C15LF2WG is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator working together to clean, regulate and lubricate compressed air on one 1/2 inch line. This configuration is built for G1/2 (BSPP) ports, carries the fine 5 um filter element (code W) with a differential-pressure drain on the filter bowl, and uses the low-pressure regulator type fitted with an embedded square gauge scaled in psi. No reverse/check valve is fitted, a mounting bracket is included, and the bowl on the filter section is metal. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch. Across the series you can order different drain types (differential-pressure, automatic or manual), a 40 um standard or 5 um fine filter element, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Because flow is published as curves rather than a single rating, we confirm the datasheet and sizing figures for your application on request.

GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um Technical Specifications

ModelGC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um Is Used

factory

Packaging machine actuator supply

On a cartoning or wrapping line, the filter strips water and fine particles from the plant air, the low-pressure regulator holds a gentle supply pressure for delicate cylinders, and the lubricator mists oil to keep actuator seals and surfaces working smoothly.

precision_manufacturing

Assembly cell air tools and cylinders

At a bench or robotic assembly cell running air-driven drivers and clamps, this three-unit set cleans the incoming air to 5 um, regulates it at low pressure for the tool circuit, and feeds a controlled oil mist to extend tool life.

conveyor_belt

Conveyor and gate cylinder circuit

On a bottling or food-plant conveyor with air-operated gates and pushers, the combination conditions the line air in one pass: filtered to 5 um, held at the low pressure the gate cylinders need, and lubricated for continuous cycling.

Is the GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um the Right Station?

Start with size and port: the 400 size with its 1/2 inch port suits lines where larger flow is needed, while 200/300 sizes cover smaller ports and 600 covers 3/4 and 1 inch. Choose the drain on the filter bowl - differential-pressure (as here, the default), automatic for unattended draining, or manual where an operator drains by hand. Pick the filter grade: 40 um standard or 5 um fine (this unit is the 5 um W grade) where downstream equipment needs cleaner air. Select the gauge scale (MPa, psi or bar) and the thread standard - PT is the AirTAC standard, with G (BSPP) and NPT available as order options. Note that this is the low-pressure regulator type; the exact adjustment range for that type is not published in the summary data, so ask us to confirm it. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one flow number we can honestly quote. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing from the datasheet on request before you order.

The W in the code selects the fine 5 um filter element instead of the 40 um standard, and the gauge code selects the embedded square gauge scaled in psi (MPa and bar scales are also available). The low-pressure regulator type and G (BSPP) thread are likewise order choices - PT is the AirTAC standard thread, with G and NPT as catalogue options. Ask us to confirm the low-pressure adjustment range from the datasheet.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15LF2WG AirTAC F.R.L. Unit G1/2 Low-Pressure 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15LF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.