The AirTAC GC400C15MF2 AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC400C15MF2 is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one prepared-air station. This size 400 unit is ported PT1/2 with PT (BSPP-equivalent JIS) thread as the standard connection. The filter element is the standard 40 um grade, and the filter bowl uses a manual drain, so an operator opens the drain valve to remove collected condensate during checks. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and the fitted embedded square gauge reads in psi so setpoints can be checked at a glance. The lubricator adds a fine oil mist downstream to keep air tools and cylinders running smoothly. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with options including automatic or differential-pressure drains, a 5 um (W) filter element, gauge scale in MPa, psi or bar, and G or NPT thread variants ordered to specification. Rated flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet and flow data for your application on request.
| Model | GC400C15MF2 AirTAC F.R.L. Combination, PT1/2 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Installed at the drop of a machine shop air ring, the GC400C15MF2 dries and filters the supply to 40 um, holds a set regulator pressure read on the psi gauge, and mists oil to the spindle clamps and pneumatic actuators on the machining cell.
Mounted on the frame of a carton-forming and sealing line, this three-unit station filters water and particulate from the plant air, regulates the pressure feeding the sealing and pusher cylinders, and lubricates them for continuous shift operation.
At a workbench air drop in an assembly plant, the GC400C15MF2 conditions the supply before it reaches impact wrenches and air ratchets: filtered to 40 um, regulated to the tool setpoint on the psi gauge, and carrying a fine oil mist to extend tool life.
Choose the size and port step against the air demand of the circuit: this GC400C15MF2 is the size 400, PT1/2 station, with larger sizes (600) and smaller sizes (200/300) available when the line requires a different port. Drain type is a real choice: this unit has a manual drain, which suits lines with scheduled maintenance checks; automatic and differential-pressure drains are available on other codes where condensate must be removed without operator attention. The filter element here is the standard 40 um grade; specify the 5 um (W) grade where downstream equipment needs finer filtration. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are order options. PT thread is standard on this code, with G and NPT variants available to order.
Sizing note: flow for the GC series is published as curves, not as a single rated figure, so we cannot quote one number here. Send us your application details and we will confirm the flow and datasheet figures against your requirement before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the flow data from the datasheet for this size 400, PT1/2 unit on request.
The M in GC400C15MF2 codes a manual drain on the filter bowl: condensate is removed when an operator opens the drain during routine checks, which suits lines with scheduled maintenance. If your line runs unattended, ask about GC codes with an automatic (A) or differential-pressure (blank) drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.