verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15MF2W AirTAC F.R.L. Combination, PT1/2

The AirTAC GC400C15MF2W AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$138.28 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15MF2W AirTAC F.R.L. Combination, PT1/2

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built up as one unit, so the incoming compressed air is cleaned of water and particulate, regulated to the working pressure, and carries a fine oil mist to downstream cylinders, valves and air tools. This GC400C15MF2W is the size 400 unit with a 1/2 in PT thread, a manual-drain filter bowl in polycarbonate, the 5 um filter element (the finer of the two grades), a standard regulator with the embedded square gauge reading in psi, and the mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard or 5 um), gauge scale (MPa, psi or bar) and G (BSPP) or NPT thread in place of the PT standard. Flow for this combination is published as characteristic curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GC400C15MF2W AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC400C15MF2W AirTAC F.R.L. Combination, PT1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15MF2W AirTAC F.R.L. Combination, PT1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15MF2W AirTAC F.R.L. Combination, PT1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Point-of-use conditioning for a CNC machining centre: the filter removes water and swarf-laden dirt before the regulator sets the working pressure for the tool changer and clamping cylinders, and the lubricator meters oil mist to the actuated components.

conveyor_belt

Carton packaging conveyor drives

Conditioning the air feeding pneumatic grippers, diverters and pushers on a carton packaging conveyor: the 5 um element protects the pilot valves, the regulator holds a steady supply pressure, and the lubricator serves the cylinders running all shift.

air

Automotive paint booth drops

Conditioning the air at each drop feeding spray guns and air motors in an automotive paint booth: the 5 um grade suits finishing work, the manual-drain bowl suits a station that is checked at the start of every shift, and the regulator sets gun supply pressure.

Is the GC400C15MF2W AirTAC F.R.L. Combination, PT1/2 the Right Station?

The meaningful choices on a GC unit are all decodable from the code. Size 400 with a 1/2 in PT port sits in the middle of the 200/300/400/600 range; step a size up or down when the air demand of the downstream circuit changes, and ask us to check the published flow curves against your consumption before ordering. The M code fits the manual drain, so the filter bowl is emptied by hand on a routine; if the unit will be mounted out of reach or run unattended, choose the automatic (A) or differential-pressure (blank) drain version instead. The W code selects the 5 um element rather than the 40 um standard - take 5 um where fine pilot valves and cylinders need cleaner air, 40 um where bulk water and coarse dirt are the main concern. The square gauge on this unit reads in psi; MPa and bar scales are available. PT is the standard thread, with G (BSPP) and NPT as order options, and the mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15MF2W AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for the GC400 as characteristic curves, not as a single rated figure, so we do not quote a number on the page. Tell us your working pressure and the air consumption of the downstream equipment and we will confirm the sizing from the datasheet on request before you order.

M is the manual drain: the filter bowl is emptied by hand, so someone must open the drain on a routine to release collected water. If the unit will be out of reach or run unattended, order the automatic (A) or differential-pressure (blank) drain version instead. Note the regulator range differs by drain type: this manual-drain unit adjusts 0.05-0.9 MPa (7-130 psi), while automatic and differential-pressure drain versions adjust 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15MF2W AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15MF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.