verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.29 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled into one supply unit. This configuration is built for a 1/2 in port with G (BSPP) thread, carries the W-grade 5 um filter element for finer water and particulate removal, and uses a manual drain on the filter bowl. The regulator is the low-pressure type, fitted with an embedded square gauge scaled in psi, and a reverse/check valve is included. A mounting bracket is supplied, and the filter section uses a metal bowl.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, threads (PT standard; G and NPT as order options), drain types, filter grades and gauge scales. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2 Technical Specifications

ModelGC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2 Is Used

factory

Automotive assembly line air drops

Feeding pneumatic impact wrenches, nut runners and air ratchets at a vehicle assembly drop, where the 5 um element protects tools from water and grit, the regulator holds a steady low working pressure, and the lubricator mists oil into the tool air supply.

conveyor_belt

Packaging and case-packing conveyors

Supplying the clamp cylinders, pushers and diverters on a packaging conveyor, where stable regulated pressure keeps actuator stroke behaviour consistent through the shift and the lubricator reduces wear on high-cycle cylinders.

engineering

Machine shop workholding circuits

Serving pneumatic clamps and vise cylinders on CNC machining fixtures, where clean, moisture-reduced air at a set low pressure is needed for repeatable clamping, and the manual drain suits a workshop with a daily check routine.

Is the GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2 the Right Station?

Start with the port step: size 400 with a 1/2 in port suits lines that need more flow than the 200/300 sizes deliver - match the size to the air demand of the downstream equipment rather than the pipe alone. This unit already fixes several choices: 5 um filtration (the finer W grade, instead of the 40 um standard), a manual drain (simple and low-cost, but the bowl must be drained by hand rather than automatically), a low-pressure regulator with a square psi gauge, and a reverse/check valve. If you would prefer automatic or differential-pressure draining, a 40 um element, a different gauge scale (MPa or bar), or PT or NPT thread instead of G, those are decodable options in the series - tell us and we will identify the matching code.

One honest note on sizing: AirTAC publishes flow for this series as curves, not as a single rated number, so we cannot quote a rated flow figure. Send us your application details and we will confirm the correct size and the datasheet figures on request.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2 FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and downstream air demand, and we will confirm the correct sizing and provide the datasheet flow curves on request.

The M in the code specifies a manual drain on the filter bowl: condensate is released by hand, which is simple and reliable but requires someone to drain the bowl as part of routine checks. The GC series is also decodable with automatic or differential-pressure drains - if you would rather not rely on manual draining, contact us and we will identify the matching automatic-drain code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15MLF2WGK AirTAC F.R.L. Combination, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15MLF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.