verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure

The AirTAC GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$199.18 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure

The GC60020LC2WK is an AirTAC GC-series three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator built as one unit. This 600-size configuration is ported PT3/4 and carries the W-coded element, so incoming air is filtered to 5 um before it is regulated and lubricated. The differential-pressure drain bleeds collected water from the aluminium alloy bowl as air flows through, the low-pressure type regulator suits processes that run at reduced working pressure, and the fitted round gauge reads in psi. A reverse/check valve is fitted to hold downstream pressure if the supply drops. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The mounting bracket is included.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and with options covering drain type, 40 um or 5 um filtration, gauge style and scale (MPa, psi or bar), PT, G or NPT thread, standard or low-pressure regulation, and a reverse/check valve. Flow for the series is published as curves rather than a single rated figure, so share your application details and we will confirm sizing and datasheet figures on request.

GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure Technical Specifications

ModelGC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 5 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure Is Used

factory

Automotive paint and finishing lines

Spray booths and paint kitchens need air that is fine-filtered and steadily regulated before it reaches the guns. This unit filters to 5 um, holds the pressure the booth calls for, and meters oil mist to keep gun and valve internals working smoothly.

precision_manufacturing

Machine-shop air tool circuits

Impact wrenches, die grinders and other shop-air tools last longer on lubricated air. This GC600 unit filters, regulates and oils the 3/4 inch main feeding the tool stations, with the check valve holding downstream pressure if the compressor unloads.

view_module

Packaging and bottling line actuation

Case packers, cappers and conveyor diverters run dozens of cylinders and valves per shift. A 5 um element protects the directional valves, the regulator holds a steady working pressure, and the lubricator mists the cylinder seals.

Is the GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure the Right Station?

Choose the size by port and demand: this unit is size 600 with a 3/4 inch PT port, the largest step in the range, for lines with substantial air consumption; the 200/300/400 sizes cover lighter circuits. Drain options are differential-pressure (fitted here, bleeding the bowl as air flows), automatic (A) or manual (M). Filtration is 5 um on this W-coded unit; the standard element is 40 um if your valves tolerate coarser air. The regulator on this unit is the low-pressure type - if your process runs at ordinary working pressures, the standard type may be the better match; ask us to confirm the range. Gauge choices are embedded square or external round, scaled in MPa, psi or bar (this unit: round, psi). Thread is PT as standard, with G (BSPP) and NPT as order options, and a reverse/check valve (K) is fitted. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can quote honestly. Send us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the sizing from the datasheet on request.

The L code marks the low-pressure version of the regulator. The exact adjustment range for this variant is not published in the material we hold, so tell us the working pressure your process needs and we will confirm suitability on request before you order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC60020LC2WK AirTAC F.R.L. Combination, PT3/4 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60020LC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.