The AirTAC GC60025C2 AirTAC F.R.L. Combination, PT1 in Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC60025C2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 3-piece set. This configuration is the size 600 unit with a PT1 (1 inch) PT-threaded port, a 40 um standard filter element, a differential-pressure drain on the filter bowl, and a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range. Because it is the 600 size, the filter bowl is aluminium alloy, and the code C2 specifies an external round pressure gauge with a psi scale. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with matching port sizes, and options include a 5 um filter element (code W), automatic or manual drains, G or NPT thread variants, gauge scale choices and reverse/check valve fitment. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request before you order.
| Model | GC60025C2 AirTAC F.R.L. Combination, PT1 in Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Installed at the main air preparation point of a manufacturing plant, the three units clean water and particulate from the compressed air, hold a steady regulated pressure for the distribution header, and carry oil mist downstream to keep air tools and actuators lubricated across the shop floor.
On heavy pneumatic presses, clamping fixtures and forming equipment fed from a 1 inch air line, this combination conditions the incoming air, sets the working pressure the machine was designed for, and lubricates the cylinders and valves that do the work each cycle.
On bottling, cartoning and conveyor systems with many air cylinders running continuously, the set removes condensate and debris, keeps line pressure stable so index and stop cylinders act consistently, and delivers oil mist to extend the life of the valves and actuators along the line.
Start with the size and port: the 600 size carries the largest port in the range (PT1, 1 inch), so step up to it when your line's air demand sits above what 3/4 in and smaller ports serve; ask us to confirm sizing against the published flow curves before ordering. Choose the drain next: differential-pressure (this unit's default) bleeds the bowl as pressure drops, automatic drains continuously, and manual drain suits supervised installations. Filter grade is 40 um standard here; specify the W code for 5 um where finer particulate removal is needed. The C2 code gives you a round gauge on a psi scale; square embedded gauges and MPa or bar scales are the other options. Thread is PT as standard, with G (BSPP) and NPT available as order options, and the mounting bracket is included.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the flow and datasheet figures for this 600 size, PT1 (1 inch) port unit before you order.
A blank drain position in the model code means the differential-pressure drain, which discharges collected condensate from the filter bowl as pressure drops. Automatic (code A) and manual (code M) drains are catalogue options on the GC series if your installation needs a different drain behaviour.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.