The AirTAC GC60025MF2K AirTAC F.R.L. Combination, PT1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC60025MF2K is a three-piece F.R.L. combination that filters water and particulate from compressed air, regulates downstream pressure, and adds oil-mist lubrication in one assembly. This size 600 unit is built around a PT1 (1 in) port, the largest step in the G-series range, and this configuration carries a manual drain on the filter bowl, the standard 40 um filter element, and an aluminium alloy bowl. Regulation is the standard type with an adjust range of 0.05-0.9 MPa (7-130 psi), read on the embedded square gauge fitted here with a psi scale. A reverse/check valve is fitted, and the mounting bracket is included.
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard, 5 um optional), gauge scale (MPa, psi or bar), thread (PT standard, G and NPT as order options) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GC60025MF2K AirTAC F.R.L. Combination, PT1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
At the header take-off feeding a press hall, this three-unit F.R.L. cleans water and scale out of the main air, holds a set working pressure for the press clamps and air cylinders, and mists oil to the actuated tooling downstream.
Mounted at the tool drop on an assembly line, the unit conditions the supply to impact wrenches and nutrunners: the 40 um element stops particulate reaching the tools, the regulator holds consistent torque-setting pressure, and the lubricator feeds the tool motors.
Installed ahead of the valve bank that drives conveyor stops, pushers and palletiser grippers, the combination keeps condensate and dirt out of the valves, pins the circuit pressure for repeatable cylinder stroke speed, and lubricates the actuator seals.
Start with the port and size step: this unit is size 600 with a PT1 (1 in) port, the top of the G-series range, so step down to a smaller size only if your line flow allows it - and since flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. The drain here is manual, which means someone bleeds the bowl on a routine; if unattended drainage matters, the automatic or differential-pressure drain codes are the alternatives to specify. Filter grade is the standard 40 um element; the W code gives a 5 um element where finer filtration is needed. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are the other gauge choices. Thread is PT as standard, with G (BSPP) and NPT available as order options, and the mounting bracket is included on this configuration.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing against the datasheet curves on request before you order.
A manual drain means the filter bowl is bled by hand on a routine, which suits attended cells and lines visited daily. If the unit sits in an unattended location where skipped drains would let condensate carry over, specify the automatic (code A) or differential-pressure (blank) drain version instead - the rest of the GC60025MF2K specification stays the same.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.