The AirTAC GC600C20AC2 AirTAC F.R.L. Combination, PT3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC600C20AC2 is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. It cleans compressed air of water and particulate down to the standard 40 um grade, regulates downstream pressure across the 0.15-0.9 MPa (20-130 psi) range, and adds oil mist for air-powered tools and actuators. This size 600 configuration has a PT3/4 port, an automatic drain that expels collected condensate without manual attention, a metal bowl (aluminium alloy at size 600), a fitted round gauge reading in psi, and an included mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600, with choices of drain type (differential-pressure, automatic or manual), a 5 um filter grade option (code W), gauge scale in MPa, psi or bar, and G (BSPP) or NPT thread options to order alongside the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GC600C20AC2 AirTAC F.R.L. Combination, PT3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeding filtered, regulated and lubricated air to spray-booth and paint-line equipment, where water and grit in the supply would ruin finish quality and the automatic drain keeps condensate off the work.
Conditioning the air feeding pneumatic cylinders on a carton-forming and wrapping line, holding a stable regulated pressure so sealing and clamping strokes repeat consistently through the shift.
Supplying clean, regulated, oil-misted air to the pneumatic clamps, tool-change cylinders and air-blast nozzles on a machining centre, with the psi gauge giving operators a visible line-pressure check.
Start with the size and port: 600 is the largest step in the GC range and carries a 3/4 in port, so match it against your line's flow demand and existing pipe size. Choose the drain to suit access: automatic (this unit) suits installations that are not checked daily, manual suits supervised points, and differential-pressure draining is the catalogue default. The 40 um grade is standard; specify the 5 um W grade where downstream equipment needs finer filtration. The round gauge here reads psi; MPa and bar scales are alternatives, and the embedded square gauge is the standard fitting. Thread is PT as standard, with G (BSPP) and NPT available as order options, and a mounting bracket is included.
Because flow is published only as curves and not as a single rated number, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your application and operating pressure and we will confirm the flow and datasheet figures for this unit on request before you order.
The automatic drain expels collected condensate by itself, which suits installations that are not checked every day; manual and differential-pressure drains are the other catalogue choices. The filter grade on this unit is the 40 um standard, and the finer 5 um grade is available as the W code option if your equipment needs it.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.