The AirTAC GC600C20AF2WGK AirTAC F.R.L. Combination Unit, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC600C20AF2WGK is a three-unit F.R.L. combination that conditions compressed air in three separate stages: a filter that removes water and particulate, a pressure regulator, and an oil-mist lubricator. This size 600 configuration carries a G3/4 port with G thread, an automatic drain on the filter bowl so collected condensate is expelled without manual attention, a fine 5 um filter element (the 40 um standard element is also available in the series), an embedded square gauge reading in psi, a reverse/check valve fitted on the regulator, and a mounting bracket included. The bowls on this size 600 unit are aluminium alloy, and the maximum working (inlet) pressure is 1.0 MPa (145 psi) with an operating temperature range of -5 to 70 C, non-freezing. The standard regulator adjustment range with automatic drain is 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with a choice of ports, drain types, filter grades, gauge scales and thread options. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC600C20AF2WGK AirTAC F.R.L. Combination Unit, G3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeding clean, regulated and lubricated air to the clamping fixtures, tool-changer cylinders and spindle-air seals on a machining centre, where the 5 um element protects tight-tolerance components and the lubricator mists the actuator seals.
Conditioning the air that drives case packers, label applicators and conveyor diverters on a bottling hall line, with the automatic drain clearing condensate during continuous shifts and the regulator holding a steady setting downstream.
Installed at the take-off point of a plant air ring main serving impact wrenches, pneumatic presses and lift tables, where filtered, regulated and lubricated air keeps the tool circuit consistent across a large-distribution header.
Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, and this size 600 unit with its G3/4 port is the largest step, suited to lines with substantial air demand. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. Then choose the drain: automatic (as fitted here), manual, or the differential-pressure default. Choose the filter grade: 40 um standard or the finer 5 um element fitted on this unit. Select the gauge scale - MPa, psi or bar - and the thread: PT is the standard, with G and NPT as catalogue options to order. A bracket is included on this configuration. We will confirm the datasheet figures on request before you commit.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your working pressure and air demand and we will confirm the correct figures from the datasheet on request before you order.
The A in the code fits an automatic drain, so condensate collected in the filter bowl is expelled without anyone opening it - useful on unattended or continuous-duty lines. The series also offers manual drain (code M) and the differential-pressure drain as the default; the standard regulator adjustment range with automatic or differential-pressure drain is 0.15-0.9 MPa (20-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.