The AirTAC GC600C20ALC2WGK AirTAC F.R.L. Combination, G3/4 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled into one air-treatment station for compressed air. This GC600 unit is built for a G3/4 port and carries the 5 um filter element (code W) with an automatic drain, so condensate is expelled from the aluminium alloy filter bowl without manual attention. The regulator is the low-pressure type, a round psi gauge is fitted, and a reverse/check valve is installed. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600 with port options from 1/8 to 1 inch in PT, G or NPT thread, plus a choice of drain type, filter grade and gauge scale. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GC600C20ALC2WGK AirTAC F.R.L. Combination, G3/4 Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeding filtered, regulated and lubricated air to spray guns and air tools on a body-shop paint line, where the 5 um element and automatic drain keep water and particulate out of the finish work.
Supplying treatment stations for the pneumatic cylinders and grippers that move, index and cap containers on a bottling conveyor, with the lubricator keeping cylinder seals running smoothly.
Conditioning the air feeding clamps, tool-changer actuators and air bearings on a CNC machining cell, where the low-pressure regulator and round psi gauge suit circuits run below standard pressure.
The real choices in this series are decodable from the code. The size step (200/300/400/600) sets the port and the flow capacity, so step up a size when your line draws more air - we can check the published flow curve against your demand. Drain type is differential-pressure (default), automatic (this unit) or manual; filter grade is 40 um standard or 5 um with the W code. Units with a regulator take an embedded square gauge or an external round gauge in MPa, psi or bar scales - this one is round, psi. Thread is PT as standard, with G and NPT as order options. The L code selects the low-pressure regulator variant; its exact range is not published, so confirm it with us. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
Flow for this unit is published as curves in the AirTAC catalogue rather than as a single rated figure, so we do not quote a number here. Send us your line demand and we will confirm the correct size and the datasheet figures on request.
The A code in the model specifies an automatic drain, which expels condensate from the filter bowl without manual attention. Across the GC series you can also order the default differential-pressure drain or a manual drain (code M); this particular unit is built with the automatic drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.