The AirTAC GC600C20ALF2 AirTAC F.R.L. Combination, PT3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC600C20ALF2 is a three-unit AirTAC F.R.L. combination: a separate filter, regulator and lubricator assembled to condition compressed air on one supply line. This 600-size unit is ported PT3/4 (3/4 in, PT thread as standard), filters to 40 um and drains condensate automatically, so the bowl does not need blowing down by hand. The regulator is the low-pressure type and a square gauge scaled in psi is fitted. At 600 size the bowls are aluminium alloy, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options including G (BSPP) or NPT thread, a 5 um filter element (code W), manual or differential-pressure drain, gauge scale in MPa, psi or bar, and a reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GC600C20ALF2 AirTAC F.R.L. Combination, PT3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Conditioning the air feeding conveyor cylinder and gripper circuits on a bottling line, where filtered, regulated and lubricated air keeps a 3/4 in main supply clean through a full shift.
A three-unit F.R.L. on the air drop serving carton-forming and case-sealing machines, with the automatic drain handling condensate so operators are not blowing down bowls each shift.
Feeding pneumatic clamps, presses and air tools from a 3/4 in drop in a machine shop, with oil-mist lubrication carried downstream and the square psi gauge for setting line pressure.
The real choices on this series are decodable from the code. Step through sizes 200/300/400/600 to match the port and the flow your line needs - this unit is 600 size with a PT3/4 port. Drain types are differential-pressure (default), automatic (this unit) or manual; filter grade is 40 um standard or 5 um with code W; gauges are an embedded square gauge with an optional external round gauge, scaled in MPa, psi (this unit) or bar. Thread is PT as standard, with G (BSPP) and NPT as order options, and a bracket is included. The regulator here is the low-pressure type; its exact adjustment range is not published in the catalogue, so confirm it with us before ordering. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and the flow your application needs, and we will confirm the sizing from the datasheet before you order.
It marks the low-pressure type of regulator. The exact adjustment range for this low-pressure variant is not published in the catalogue, so ask us to confirm it against your set pressure. The rest of the code reads A for automatic drain and F2 for the square gauge scaled in psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.