The AirTAC GC600C20F2WG AirTAC F.R.L. Combination, G3/4 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC600C20F2WG is a three-piece F.R.L. air-treatment combination: a separate filter, pressure regulator and lubricator assembled as one supply unit. The filter stage removes water and particulate down to 5 um (the finer W grade, in place of the 40 um standard element), the standard regulator holds downstream pressure within its 0.15-0.9 MPa (20-130 psi) adjustment range, and the lubricator feeds an oil mist to downstream air tools and cylinders. This size-600 configuration is fitted with G3/4 (BSPP) ports, an embedded square gauge reading in psi, differential-pressure drains on the bowl, and a mounting bracket. The bowls on this 600 size are aluminium alloy, and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at temperatures from -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of port sizes, PT (standard), G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge scale in MPa, psi or bar, and optional reverse/check valve. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GC600C20F2WG AirTAC F.R.L. Combination, G3/4 Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the spray-booth and conveyor air rings on a paint line, where the 5 um element protects finish quality and the lubricator keeps actuators moving smoothly.
Supplies the pneumatic clamps, tool-changers and chip-suction cylinders on a machining centre, with the regulator holding a steady clamp pressure and the psi gauge giving operators a direct readout.
Conditions the air feeding diverters, pushers and stopper cylinders on a bottling or packaging conveyor, combining water and particle removal, set pressure and oil mist in one 3/4-in supply point.
Work from the air consumption of the downstream equipment first: step up through sizes 200, 300, 400 and 600, each with a larger port (here 3/4 in, G thread), until the size covers the demand. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order. Then settle the decodable choices: drain type (differential-pressure as fitted here, or automatic or manual), filter grade (the 5 um W element on this unit, or the 40 um standard), gauge scale (this unit reads psi; MPa and bar scales exist), thread (PT is the standard; G and NPT are order options), and bracket. This unit includes its mounting bracket.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a flow figure. Tell us your application and air demand and we will confirm the datasheet flow curve and correct size for you before you order.
The W in the model code GC600C20F2WG selects the optional 5 um filtration element in place of the 40 um standard. Choose 5 um where downstream valves, instruments or finish-sensitive equipment need finer particle removal; the 40 um grade remains the standard choice for general plant air.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.