verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure

The AirTAC GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$211.97 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure

The GC600C20LF2K is a genuine AirTAC three-unit F.R.L. combination that conditions compressed air in one assembly: a filter removes water and particulate down to 40 um, a low-pressure regulator holds your set pressure, and a lubricator feeds an oil mist downstream. This 600-size unit is built with a 3/4 in PT port, a differential-pressure drain on the filter bowl, an embedded square gauge reading in psi, and a reverse/check valve fitted to hold downstream pressure. The aluminium alloy bowls on the 600 size suit demanding installations.

This is a genuine AirTAC part in the largest of the four G-series sizes (200/300/400/600), which also come in smaller ports, PC or aluminium bowls, manual or automatic drains, a 5 um filter grade (code W), and G or NPT thread options. Rated inlet pressure is 1.0 MPa (145 psi) with a working temperature of -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet before you order.

GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure Technical Specifications

ModelGC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure Is Used

factory

Heavy press air preparation

Conditioning the plant air feeding a stamping or forming press cell: the filter strips water and 40 um-plus particulate from the header supply, the low-pressure regulator holds the circuit setpoint, and the lubricator mists oil to the press cylinders.

conveyor_belt

Packaging conveyor actuation

Supplying treated air to a packaging or bottling line's conveyor actuators and clamp cylinders, where the check valve holds downstream pressure during supply dips and the psi gauge lets technicians verify setpoint at a glance.

local_shipping

Fleet service bay supply

Mounted at the garage-air drop of a truck or bus maintenance bay, the 3/4 in F.R.L. feeds impact wrenches and lift controls with filtered, regulated, lubricated air while the differential-pressure drain keeps the metal bowl clear of condensate.

Is the GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure the Right Station?

Size 600 with a 3/4 in PT port is the top step of the G-series ladder - choose it when your line's flow demand sits above what a 400-size unit serves, and step down to 200/300/400 if your port and flow are smaller. This configuration is the low-pressure type (code L), so confirm the operating band suits your circuit; the exact regulation range for this variant is not published and we will confirm it on request. The drain is differential-pressure (the default), which bleeds the bowl automatically as pressure drops - pick automatic (A) or manual (M) variants if your maintenance routine prefers them. The 40 um standard filter grade is right for general plant air; choose the 5 um W-grade variant where downstream valves and cylinders need finer protection. The square gauge reads in psi; MPa and bar scales and an external round gauge are alternatives. Thread is PT as standard, with G (BSPP) and NPT available to order, and the mounting bracket is included.

Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request before you order.

The L in the code marks the low-pressure regulator variant, suited to circuits that run below standard plant pressure; its exact regulation range is not published, and we will confirm it on request. The K code means a reverse/check valve is fitted, which holds downstream pressure if the upstream supply fails. This unit also carries a square gauge reading in psi, a differential-pressure drain, and a 40 um filter element as standard.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20LF2K AirTAC F.R.L. Unit 3/4" PT Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20LF2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.