verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4

The AirTAC GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4

The AirTAC GC600C20MC2WG is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply unit. This size 600 configuration is built around a G3/4 (BSPP) port and carries the 5 um filter element (code W) instead of the 40 um standard element, so it strips finer water and particulate from the compressed air before regulation. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and because the drain is the manual type (code M) the bowls are emptied by hand on your maintenance schedule. A round gauge with a psi scale is fitted so the set pressure can be read directly, and the bowls on this 600 size are aluminium alloy. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with matching port sizes, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filter grades, gauge scale options, and PT, G or NPT threads. Flow is published in the AirTAC catalogue as curves rather than a single rated figure, so ask us to confirm the flow and datasheet details for your application before ordering.

GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4 Technical Specifications

ModelGC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4 Is Used

precision_manufacturing

CNC machining cell air supply

A machine shop feeds its CNC machining centres and pneumatic clamps from a G3/4 main, using this unit to remove water and fine particles at 5 um, hold a steady regulated pressure for clamping repeatability, and deliver a light oil mist to keep air cylinders and tools running smoothly.

conveyor_belt

Bottling and packaging line actuation

On a high-cycle bottling line, pneumatic grippers, diverters and case packers run continuously off a 3/4 inch header; this combination conditions the supply with fine filtration, keeps actuator pressure stable through shift-long cycles, and lubricates the cylinders to extend service intervals.

factory

Pneumatic press and forming operation

A fabrication plant runs pneumatic presses and forming tools from a plant-air ring main; this unit filters the incoming air at 5 um, regulates working pressure to the set point with the fitted psi gauge under manual-drain maintenance, and oils the downstream cylinders for consistent stroking.

Is the GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4 the Right Station?

Start with the port and size step: this unit is size 600 with a G3/4 port, the largest step in the range, so choose GC600 when your line's air demand calls for the bigger ports and the 200/300/400 steps are too small. Filter grade is a real choice: 40 um is the standard element, while the W code on this model selects the finer 5 um element for cleaner air downstream. Drain type matters to maintenance: differential-pressure drain is the default, automatic drain empties itself, and the manual drain on this unit (code M) means an operator drains the bowls on a schedule. You can also choose the gauge (embedded square or external round) and its scale (MPa, psi or bar - this unit reads psi), the thread (PT is the standard; G and NPT are order options), and whether a mounting bracket is included. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4 FAQ

AirTAC publishes flow for this series as performance curves in the catalogue, not as a single rated number, so we do not quote a figure here. Tell us your application and air demand and we will confirm the flow from the datasheet so you can size the unit correctly before ordering.

The M in the code selects the manual drain: an operator drains the bowls on a maintenance schedule instead of relying on the default differential-pressure drain or the automatic-drain option. The W selects the finer 5 um filter element in place of the 40 um standard element, for cleaner air to the regulator and lubricator and the equipment downstream.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20MC2WG AirTAC F.R.L. Combination Unit G3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.