verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port

The AirTAC GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.09 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port

The GC600C20MF2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This 600-size unit is built around G3/4 ports and carries the standard 40 um filter element, which removes water and particulate from the compressed air before it reaches the regulator and lubricator. The manual drain lets an operator empty collected condensate from the filter bowl on demand, the standard regulator covers an adjustment range of 0.05-0.9 MPa (7-130 psi), and the lubricator meters oil mist into the air line to serve downstream pneumatic tools and actuators. A square pressure gauge scaled in psi is fitted, and the metal filter bowl (aluminium alloy at size 600) suits applications where a polycarbonate bowl is not preferred.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port options, drain types (differential-pressure, automatic or manual), filter grades (40 um standard, 5 um optional), gauge scales (MPa, psi or bar) and thread variants (PT standard, G and NPT as order options). Maximum working inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.

GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port Technical Specifications

ModelGC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port Is Used

factory

Automotive assembly plant air drops

Feeds filtered, regulated and lubricated air to impact wrenches, nutrunners and clamping fixtures at assembly stations, with the manual drain emptied during shift-end checks.

precision_manufacturing

CNC machine shop pneumatic circuits

Supplies conditioned air to machine-tool clamping, tool-change and chip-clearing cylinders, where the regulator holds set pressure and the lubricator serves the actuators.

conveyor_belt

Packaging and bottling line actuators

Prepares the air feeding conveyor diverters, case packers and sealing heads on a packaging line, with the 40 um element and manual drain maintained as part of line housekeeping.

Is the GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port the Right Station?

Choose the GC three-unit format when the application needs filtration, regulation and lubrication together. Size 600 with G3/4 ports is the largest step in the range, so match it to the line size and the air demand of the downstream equipment; smaller sizes 200/300/400 step down in port and flow. This configuration has a manual drain, which suits installations where an operator can bleed the filter bowl as part of routine checks; if the unit will be mounted where regular access is difficult, an automatic-drain variant is a better choice. The standard 40 um element is the general-purpose grade; specify the 5 um (W) option where finer particulate removal is required. The fitted square gauge is scaled in psi, and MPa or bar scales are available as alternatives. Thread is G here, with PT standard and NPT available to order, and a mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so there is no one rated flow number we can quote. Send us your line pressure and the air demand of your equipment and we will confirm the flow and datasheet figures for this unit on request before you order.

The M in the code GC600C20MF2G specifies a manual drain on the filter bowl, meaning condensate is emptied by hand when needed. If the unit will be installed where regular access is impractical, the GC series is also available with automatic or differential-pressure drains - tell us the mounting situation and we will help you pick the right drain type.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20MF2G AirTAC F.R.L. Combination, G3/4 Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.