verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20MF2GK AirTAC F.R.L. Combination, G3/4

The AirTAC GC600C20MF2GK AirTAC F.R.L. Combination, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$211.44 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20MF2GK AirTAC F.R.L. Combination, G3/4

The GC600C20MF2GK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This 600-size unit is built for G3/4 ports and carries a 40 um filter element with a manual drain on the aluminium alloy bowl, a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi) with an embedded square gauge scaled in psi, and an oil-mist lubricator. A reverse/check valve is fitted and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series is also available in 200, 300 and 400 sizes, with a choice of port and thread (PT standard; G and NPT as order options), drain type (differential-pressure, automatic or manual), 5 um filtration (code W), gauge scale, and a low-pressure regulator type. Rated flow is published as curves rather than a single figure, so we confirm flow and datasheet details on request before you order.

GC600C20MF2GK AirTAC F.R.L. Combination, G3/4 Technical Specifications

ModelGC600C20MF2GK AirTAC F.R.L. Combination, G3/4
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20MF2GK AirTAC F.R.L. Combination, G3/4

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20MF2GK AirTAC F.R.L. Combination, G3/4 Is Used

factory

Automotive paint line supply

Placed at the head of the air drop feeding spray booths and air-assisted applicators, this unit cleans water and particulate from the supply, holds a steady set pressure for consistent atomisation, and carries oil mist downstream to keep air motors and actuators on the line running smoothly.

conveyor_belt

Packaging and carton-sealing line

Mounted on the supply to a packaging line's pneumatic cylinders, clamps and flap-folders, this combination removes condensate and debris, keeps the regulated pressure stable as multiple stations cycle, and lubricates the cylinder seals and valves that see continuous daily duty.

precision_manufacturing

CNC machine pneumatic circuits

Installed ahead of a CNC machine tool's clamping, tool-change and chip-clearing circuits, this unit delivers filtered, regulated and lubricated air so workholding and tool-change actuators receive clean, stable pressure, with the fitted check valve holding the circuit against backflow.

Is the GC600C20MF2GK AirTAC F.R.L. Combination, G3/4 the Right Station?

The real choices in this series are the size and port step (200, 300, 400, 600 - larger sizes carry larger ports and more flow), the drain type on the filter bowl (differential-pressure as standard, automatic, or manual as fitted here), the filter grade (40 um standard, 5 um with code W), the gauge (embedded square as standard, external round optional, scaled in MPa, psi or bar), the thread (PT standard, G or NPT to order), and the reverse/check valve. This 600-size configuration gives you G3/4 ports, manual drain, 40 um filtration, a psi-scaled square gauge and a fitted check valve.

Because rated flow is published as curves rather than a single number, size the unit against your actual air demand with us first: send the application details and we will confirm the flow and datasheet figures for the GC600 before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20MF2GK AirTAC F.R.L. Combination, G3/4 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow and datasheet figures for this 600-size, G3/4 unit on request.

The M in GC600C20MF2GK specifies a manual drain on the filter bowl: condensate is released by hand, which suits installations checked as part of a routine. The GC series is also ordered with a differential-pressure drain (the standard) or an automatic drain - tell us which you need and we will confirm the matching code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20MF2GK AirTAC F.R.L. Combination, G3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MF2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.