AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um

The AirTAC GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um

The GC600C20MF2WG is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 3/4-inch (G3/4) treatment train. This configuration carries the W filter element (5 um filtration instead of the standard 40 um), a manual drain on the filter bowl, a standard regulator with a 0.05-0.9 MPa (7-130 psi) adjustment range, and a fitted embedded square gauge reading in psi. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). At size 600 the filter and lubricator bowls are aluminium alloy rather than the polycarbonate used on smaller sizes, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge scales and thread options, so a configuration can be matched to most plant air-prep points. Flow for this unit is published as curves rather than a single rated figure; ask us and we will confirm the datasheet figures for your application on request.

GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um Technical Specifications

ModelGC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um Is Used

factory

Automotive assembly plant air ring main

Dropping a treated branch off a 3/4-inch plant air main to feed impact wrenches, nutrunners and air balers at assembly stations: the filter removes water and 5 um particulate, the regulator holds a steady station pressure, and the lubricator carries a fine oil mist to the tools.

conveyor_belt

Packaging and case-sealing line

Supplying the pneumatic cylinders, grippers and vacuum ejectors on a carton-forming and case-sealing conveyor line, where clean, regulated and lubricated air keeps seal jaws, pushers and box clamps cycling consistently through a full shift.

engineering

Machine-shop pneumatic clamping fixtures

Feeding the air-actuated clamps and swing cylinders on CNC workholding fixtures, where the regulator pins clamp pressure for repeatable holding force, the 5 um element protects precision valve spools, and the lubricator conditions the cylinder seals.

Is the GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um the Right Station?

Start with the port step: size 600 with a G3/4 connection is the largest G-series frame, so match it against the air demand of the circuit it will feed - and because flow is published as curves rather than one rating, ask us to confirm sizing against your application before ordering. The remaining choices are all decodable from the code: drain type (manual here, with automatic and differential-pressure available on other variants), filter grade (5 um on this W variant versus the 40 um standard), gauge scale (this unit reads psi; MPa and bar scales exist), and thread (PT is the standard; G and NPT are catalogue options to order). If your air tools or cylinders need consistent lubrication downstream of clean, regulated air, a three-piece GC set is the right family; if you do not need lubrication, a GFR filter-regulator alone may suffice.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um FAQ

AirTAC publishes flow for the GC600 as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the datasheet flow figures for this exact model on request before you order.

The M in this code specifies a manual drain on the filter bowl: collected condensate is released by operating the drain by hand as part of routine checks. Other GC variants offer automatic or differential-pressure drains that discharge condensate without operator action; manual drain is chosen where the unit is accessible and inspection visits are already scheduled. Note the manual-drain regulator adjustment range is 0.05-0.9 MPa (7-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20MF2WG AirTAC F.R.L. Combination, G3/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.