The AirTAC GC600C20MF2WGK AirTAC F.R.L. Combination Unit, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC600C20MF2WGK is a three-piece AirTAC F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply unit. This configuration is built for 3/4 in G-thread ports, filters to 5 um, uses a manual drain on the filter bowl, carries an embedded square gauge reading in psi, and includes a reverse/check valve so downstream pressure is held if the upstream supply drops. At size 600 the filter and lubricator bowls are aluminium alloy, and a mounting bracket is included.
This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, drain types, 40 um or 5 um filtration, gauge styles and scales, and an optional reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC600C20MF2WGK AirTAC F.R.L. Combination Unit, G3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeding spray guns and air-driven agitators on a paint line: the 5 um element and lubricator keep the air clean and the tools oiled, while the regulator holds a steady set pressure at the booth.
Supplying cylinders and vacuum generators on a carton-forming and sealing conveyor, where the check valve holds the circuit during brief upstream dips and the manual drain is emptied at shift checks.
Powering clamps and workholding fixtures on a machining centre, with the psi gauge giving the operator a direct read of clamping pressure and the lubricator protecting the valve-and-cylinder stack.
Start with the port and size: this unit is the 600 size with 3/4 in ports, the largest step in the GC range, so size up or down (200/300/400/600) according to the flow your line needs. The manual drain here means someone vents the filter bowl on a routine basis; if nobody can do that reliably, choose an automatic or differential-pressure drain code instead. Filtration is the 5 um element (code W) rather than the 40 um standard, which suits finer downstream equipment; the square gauge reads psi, with MPa or bar scales available as alternatives. Thread is G (BSPP); PT is the standard and NPT is an order option. A bracket is included, and the reverse/check valve is fitted.
One honest note before you order: AirTAC publishes flow for this series as curves, not as a single rated number, so we do not quote a flow figure here. Send us your flow and pressure requirements and we will confirm the correct size against the datasheet before you commit.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your required flow and working pressure and we will confirm the datasheet figures for this 3/4 in unit on request.
The M in the code selects a manual drain: the filter bowl is vented by hand at intervals, which suits attended installations; automatic or differential-pressure drain codes exist if unattended draining is needed. The W in the code selects the 5 um filter element instead of the 40 um standard, giving finer particle removal for sensitive downstream equipment.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.