verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4

The AirTAC GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.26 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one conditioning train. This GC600C20MLF2WG is the size 600 unit with a G3/4 (BSPP) thread, a 5 um filter element (the W grade, finer than the 40 um standard), a manual drain on the filter bowl, the low-pressure regulator type, an embedded square gauge reading in psi, and no reverse/check valve. At size 600 the bowls are aluminium alloy, and the set includes a mounting bracket.

It is a genuine AirTAC part, rated for compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C (non-freezing). The GC family spans sizes 200 to 600, with port options from 1/8 to 1 inch, PT as the standard thread and G or NPT as order options, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um filtration, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4 Technical Specifications

ModelGC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4 Is Used

precision_manufacturing

Carton and case sealing lines

Conditioning the plant air that drives the cylinders and grippers on a carton-sealing machine: the 5 um element removes water and fines, the regulator holds a steady supply pressure, and the lubricator mists oil into the actuator air.

build

Assembly-shop impact tools

Feeding impact wrenches and nut runners at a maintenance bench: filtered, regulated air with an oil mist keeps the tool motors lubricated, while the psi gauge lets the operator set and check line pressure at the drop.

conveyor_belt

Bottling line conveyor actuators

Supplying the air cylinders that push, stop and divert bottles on a filling line: the manual-drain filter catches condensate at the point of use, and the low-pressure regulator suits circuits that run below standard plant pressure.

Is the GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4 the Right Station?

The real decisions are the size and port step against the air your line consumes, the drain type on the filter (manual here; automatic or differential-pressure are available in the family), the filter grade (5 um here versus the 40 um standard), the regulator type (this is the low-pressure version, whose exact adjustment range is not published), the gauge and its scale (square, psi here; MPa or bar scales and an external round gauge are options), and the thread (PT is standard; G and NPT are order options; this unit is G). A mounting bracket is included. Flow is published as curves, not a single rating, so send us your application's air demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application's air demand and working pressure and we will confirm the sizing from the datasheet on request.

This unit's filter carries the M code, so condensate is drained by hand - a good fit where the bowl is checked as part of a routine. The same size 600 filter is available with automatic or differential-pressure drains if you would rather not rely on an operator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C20MLF2WG AirTAC F.R.L. 3-Piece Unit, G3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MLF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.