The AirTAC GC600C25AF2WGK AirTAC F.R.L. Combination, G1" Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC600C25AF2WGK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set, so the compressed air supplied downstream is filtered, regulated and lubricated in a single installation. This configuration is the size 600 unit with a G1 (1 in) female port, G (BSPP) thread, 5 um filtration (the finer of the two catalogue grades), an automatic drain on the filter bowl, a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, an embedded square gauge with psi scale, a reverse/check valve fitted, and the mounting bracket included. The maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). At size 600 the filter bowl is aluminium alloy.
This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of thread (PT standard, G or NPT to order), drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um optional), gauge scale (MPa, psi or bar) and reverse/check valve. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GC600C25AF2WGK AirTAC F.R.L. Combination, G1" Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Installed at the point where the compressor's air line enters a plant's ring main, the three units clean, regulate and lubricate the whole supply feeding every downstream drop, with the 1 in port matching the main header and the automatic drain handling condensate at the header's low point.
Mounted on the frame of a bottling or cartoning line, the combination feeds the cylinder- and actuator-rich section of the line: the 5 um element protects tight-tolerance valves, the regulator holds a steady working pressure as line demand fluctuates, and the lubricator mists oil to the cylinders along the conveyor.
Fitted ahead of a CNC fixture's clamping circuit, the set filters the air reaching the clamping cylinders, regulates the clamping pressure within the 0.15-0.9 MPa range so workholding force is repeatable, and lubricates the clamp cylinders, with the check valve holding clamp pressure if shop air is lost.
Start with the size and port: the 600 series is the largest step in the GC range and carries a 1 in port, so match it against the pipe size and the air demand of the line - and because catalogue flow is given as curves rather than one rated number, ask us to confirm sizing against your application before ordering. Then set the options that this code already fixes: the 5 um element suits applications that need finer particulate removal than the 40 um standard; the automatic drain ejects collected condensate without manual attention, which matters where bowls are hard to reach or the supply runs unattended; the psi-scale square gauge gives local pressure readout in the unit most used on US-market panels; and the fitted reverse/check valve holds downstream pressure if the upstream supply is interrupted. Thread is G (BSPP) on this code - PT is the catalogue standard, with G and NPT available as order options - and the mounting bracket is included. If you would rather have a manual drain, the 40 um grade, a different gauge scale or a different thread, those are all decodable variations within the same series.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Send us your application's air demand and line pressure and we will confirm the flow figures from the datasheet and check the sizing against your requirement before you order.
The W in the code specifies the 5 um filtration grade, one grade finer than the 40 um catalogue standard, which suits circuits with sensitive valves or cylinders downstream. The A specifies an automatic drain, which ejects collected condensate from the filter bowl on its own rather than relying on the default differential-pressure drain or periodic manual draining - useful where the unit is mounted in a position that is awkward to reach. Both choices are standard catalogue options within the same GC600 series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.