The AirTAC GC600C25ALF2WG AirTAC F.R.L. 3-Piece Combination G1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC600C25ALF2WG is a three-piece AirTAC GC-series F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation stack. This 600-size unit is built for a G1 (1 in) port, with the filter fitted with an automatic drain and a 5 um element (the W grade; 40 um is the standard element). The regulator is the low-pressure type, and the set carries an embedded square gauge scaled in psi. Both bowls on this size are metal - aluminium alloy at size 600 - and the mounting bracket is included; no reverse/check valve is fitted.
This is a genuine AirTAC part. The GC line spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and is offered with a choice of drain type, filter grade, gauge style and scale, thread (PT standard, with G and NPT as order options) and bracket. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GC600C25ALF2WG AirTAC F.R.L. 3-Piece Combination G1 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeds spray guns and air-assisted applicators on a paint line, where the 5 um element, low-pressure regulation and oil misting support finish quality at the booth.
Conditions the air feeding pneumatic clamps and tool-change cylinders on a machining centre: water and particles removed, pressure held steady, cylinders lubricated.
Supplies the stopper, filler and label cylinders along a beverage conveyor, with the automatic drain clearing condensate between shifts without manual attention.
Size and port step up with flow: 200 through 600, with ports from 1/8 in to 1 in; this unit is the 600 size on G1 (1 in). Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. The other decodable choices are: drain type on the filter (differential-pressure standard, automatic as fitted here, or manual), filter grade (40 um standard, 5 um with the W code as fitted here), gauge style and scale (embedded square gauge standard, external round gauge optional, MPa/psi/bar scales), thread (PT is the standard; G and NPT are order options) and bracket. Note the L in this code: the regulator is the low-pressure type, so confirm the control range you need with us before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your inlet pressure and expected air consumption and we will confirm the flow from the datasheet for this 600-size, G1 (1 in) unit before you order.
It marks the low-pressure regulator type in this set. The exact control range for the low-pressure version is not published in our sheet, so tell us the working pressure you need and we will confirm suitability on request. The unit otherwise carries a 5 um filter element, automatic drain, psi-scaled square gauge and G1 (1 in) G-thread ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.