verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port

The AirTAC GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.05 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port

The AirTAC GC600C25C2G is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single assembled set: a filter with drain bowl, a pressure regulator and an oil-mist lubricator. This 600-size unit is built for a G1 (1 in) port, with 40 um standard filtration, a differential-pressure drain on the filter bowl, and a fitted round gauge reading in psi. The standard regulator adjusts between 0.15 and 0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing). At size 600 the filter and lubricator bowls are aluminium alloy.

This is a genuine AirTAC part. The GC combination is available in sizes 200, 300, 400 and 600, with a choice of port sizes, PT (standard), G or NPT threads, manual, automatic or differential-pressure drains, 40 um or 5 um (W) filter grades, and gauges scaled in MPa, psi or bar. Because rated flow is published only as curves rather than a single figure, we confirm the datasheet and flow figures for your application on request.

GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port Technical Specifications

ModelGC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port Is Used

factory

Automotive assembly plant air ring main

A 1 in branch off the plant air ring main feeding assembly stations gets clean, regulated and lubricated air at one drop, with the psi gauge giving operators a local pressure reference.

precision_manufacturing

CNC machine shop pneumatic supply

Machine tools using air for clamping, tool-change actuation and chip ejection draw from a conditioned supply where the 40 um element removes water and particulate ahead of sensitive actuators.

conveyor_belt

Bottling plant conveyor and actuator line

Conveyor diverters, stop gates and lift cylinders on a bottling line run on regulated, oil-mist-lubricated air, extending cylinder seal life on a high-cycle packaging line.

Is the GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port the Right Station?

Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, and this 600 unit carries a 1 in port, so match the size step to the air demand of the line it feeds. Then set the drain: this model uses the differential-pressure drain (automatic and manual drains are orderable alternatives on the family). Filter grade is 40 um standard; specify the W option for 5 um where finer particulate capture is needed. The gauge here is round with a psi scale; square embedded gauges and MPa or bar scales are the other catalogue choices. Thread is G on this code, with PT as the standard and NPT as an order option. Because flow is published as curves rather than a single rated number, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your operating pressure and air demand and we will confirm the flow figures from the datasheet for this exact model on request.

The blank drain position in the code selects the differential-pressure drain, which bleeds condensate from the filter bowl automatically as pressure differential builds; automatic (A) and manual (M) drains are orderable alternatives. The C2 code selects the optional external round gauge with a psi scale; the embedded square gauge and MPa or bar scales are the other catalogue choices.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C25C2G AirTAC F.R.L. Combination Unit, G1 Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C25C2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.