verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$211.41 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25F2GK is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one conditioning set. This configuration is built around a G1 (1 in) port, the largest step in the GC range, so it suits a main air drop or a high-demand machine header rather than a single small actuator. The filter element is the standard 40 um grade with a differential-pressure drain, the regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and the lubricator meters oil mist into the downstream air. A square gauge scaled in psi is fitted, a reverse/check valve is included, and the mounting bracket comes as standard. At size 600 the filter bowl is aluminium alloy, which is the metal-bowl step in the range.

This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, optional 5 um filtration (code W), automatic or manual drains, gauge scales in MPa, psi or bar, and G (BSPP) or NPT thread options alongside the PT standard. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures against your application before ordering.

GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port Technical Specifications

ModelGC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port Is Used

precision_manufacturing

CNC machining cell air supply

Installed at the drop feeding a CNC machining cell, the set removes water and chips-scale particulate, holds a steady regulated pressure to the machine's air valves, and carries oil mist to lubricate cylinders and air tools on the 1 in main.

conveyor_belt

Bottling line actuator header

Mounted on the header feeding a bottling line's conveyor stops, lifters and capper actuators, the filter clears condensate and particles, the regulator keeps clamp and grip pressures repeatable, and the lubricator conditions the cylinders running the line.

factory

Plant main-air takeoff for tool stations

Fitted where a factory's 1 in main air takeoff serves a bank of impact wrenches, grinders and air-fed workstations, the combination cleans the supply, sets a safe working pressure under the psi gauge, and delivers oil mist so the tools keep their internal lubrication.

Is the GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port the Right Station?

Start with the port and size step: this unit is the 600 size with a 1 in G-thread port, the top of the GC range, so match it to the total air demand of the circuit it feeds rather than to a single tool. Choose the drain on the filter: this unit uses the differential-pressure drain (the default), while automatic (A) and manual (M) versions exist if your installation cannot rely on a pressure differential to trigger draining. Filtration is the standard 40 um grade; specify code W if the circuit needs the 5 um option. The fitted square gauge is scaled in psi here, with MPa and bar scales available, and an external round gauge is an alternative to the embedded square type. Thread is G (BSPP) on this code; PT is the catalogue standard and NPT is an order option, so confirm the thread your pipework expects. The bracket is included and the reverse/check valve (K) is fitted.

One honest routing note: AirTAC publishes flow for this series as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not state a flow number for this unit. Send us your application's air demand and we will confirm the sizing against the datasheet on request before you order.

The trailing G on GC600C25F2GK specifies G (BSPP) threading on the 1 in ports. PT is the catalogue standard thread, and G and NPT are order options, so pick the variant that matches your pipework. This is a specification choice made at ordering, not a delivery matter.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C25F2GK AirTAC F.R.L. Combination, G1 (1 in) Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C25F2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.