verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.07 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25F2WG is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembled set: a separate filter, a separate regulator and a separate lubricator. This size 600 unit carries a G1 (1 in) port with G thread, a 5 um filter element (the finer of the two available grades), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element rises, and a fitted embedded square gauge reading in psi. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), the bowls are aluminium alloy at this size, and no reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow for this unit is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port Technical Specifications

ModelGC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port Is Used

factory

Automotive paint shop air supply

Feeding spray guns and air-assisted applicators on a paint line, where the 5 um element removes water and particulate, the regulator holds a steady set pressure, and the lubricator mists oil into the air stream.

conveyor_belt

Bottling line conveyor and gripper cylinders

Supplying the pneumatic cylinders, grippers and stopper gates along a bottling or packaging conveyor, with one G1 (1 in) combination conditioning the whole drop for filter, regulated and lubricated air.

precision_manufacturing

CNC machining cell clamping circuits

Conditioning the air feeding pneumatic clamps, tool-change actuators and workholding fixtures on a machining centre, where stable regulated pressure and oil mist keep the actuators working consistently.

Is the GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port the Right Station?

Start with the port and size step: GC units run from size 200 (1/8-1/4 in) up to size 600 (1 in), and the larger the size, the larger the port and the greater the flow capacity - match the step to the air demand of the machine or line downstream. This unit is already set for the top of the range: G1 (1 in), G thread, 5 um filtration, differential-pressure drain and a square psi gauge. If your application needs finer air than the 40 um standard element, the 5 um grade (code W) is the right choice, as selected here. Drain type is a real decision: differential-pressure (this unit) drains on pressure drop, automatic drains continuously, and manual requires an operator. Gauge scale can be MPa, psi or bar, and the embedded square gauge can be swapped for an external round gauge. Thread is PT as standard, with G (BSPP) and NPT as order options; a mounting bracket is included.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port FAQ

AirTAC publishes flow for the GC family as performance curves rather than a single rated figure, so we do not quote a flow number here. Tell us your inlet pressure and the air demand of your equipment, and we will confirm the sizing against the datasheet curves on request before you order.

The GC family offers a 40 um standard element for general protection and a 5 um element (code W) for finer air, and this unit carries the 5 um grade. Its drain is the differential-pressure type, the default choice, which discharges collected condensate automatically when the pressure drop across the element rises - no manual draining routine is needed, though automatic and manual drain variants are available in the family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C25F2WG AirTAC F.R.L. Combination, G1 (1 in) Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C25F2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.