The AirTAC GC600C25LC2WG AirTAC F.R.L. Unit, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC600C25LC2WG is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This size 600 configuration is built for a G1 (1 in) port, carries a 5 um filter element (the finer of the two published grades), drains condensate by differential pressure, and regulates with the low-pressure type regulator. A round external gauge scaled in psi is fitted, the bowls are aluminium alloy at this size, and the mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port options, thread choices (PT standard; G and NPT as order options), drain types, filter grades and gauge scales to match. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing figures for your application on request.
| Model | GC600C25LC2WG AirTAC F.R.L. Unit, G1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Feeds clean, regulated and lubricated air to the clamps, tool-changer cylinders and spindle-air-seal circuits of a machining centre, with the 5 um element protecting fine pilot valves from particulate carryover.
Prepares the air feeding gripper cylinders, diverters and stopper gates on a filling or bottling conveyor, where the lubricator keeps high-cycle actuators running through long production shifts.
Installed as the main air-preparation set on cartoning and wrapping machines, combining water and particle removal, low-pressure regulation and oil-mist lubrication at a single 1 in supply point.
Start with the port and size step: size 600 with a G1 (1 in) port is the largest step in the GC range, so match it against the air demand of the circuit - and ask us to confirm flow from the datasheet curves before ordering, since no single rated flow figure is published. Choose the filter grade for the downstream equipment: this unit carries the 5 um element (code W); the 40 um standard element is the alternative. Drain type is a real choice: differential-pressure (as fitted here), automatic or manual. For the regulator, note this is the low-pressure type; its exact adjustment range is not published in the catalogue, so confirm it with us. Gauge scale (MPa, psi or bar), thread (PT standard; G or NPT to order) and the bracket are the remaining decodable options.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and we will confirm the flow and sizing figures from the datasheet on request before you order.
The L in the code marks the low-pressure type regulator rather than the standard one. Its exact adjustment range is not published in the catalogue, so ask us to confirm it on request. The unit's maximum working (inlet) pressure remains 1.0 MPa (145 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.