verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$211.57 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC600C25LC2WGK is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator working together to clean, regulate and lubricate compressed air on one supply line. This size 600 configuration is built around a G1 (1 in) port with G thread, the largest standard step in the G-series range. The filter carries a 5 um element (the W grade, versus the 40 um standard) with a differential-pressure drain, and its bowl is aluminium alloy, as is the case for all size 600 bowls. The regulator is the low-pressure type, fitted with a round external gauge scaled in psi, and a reverse/check valve is fitted. A mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with a choice of port, thread (PT standard; G and NPT are order options), drain type, filter grade, gauge style and scale, and with or without a reverse/check valve. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.

GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port Technical Specifications

ModelGC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port Is Used

factory

Automotive paint shop air drops

Feeding spray guns and air-assisted applicators on a paint line, where the 5 um element, regulated pressure and oil misting together condition the air reaching the finish.

conveyor_belt

Canning and packaging line actuators

Supplying the pneumatic cylinders and grippers that run case packers and conveyor diverters, giving the line filtered, regulated and lubricated air at a stable setpoint.

precision_manufacturing

Machine shop CNC air supply

Conditioning the shop-air feed to CNC machining centres and pneumatic clamping fixtures, where clean, correctly pressurised and lubricated air protects tool changers and clamps.

Is the GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port the Right Station?

Start with the port step: size 600 with a G1 (1 in) port is the largest G-series frame, so match it against the air demand of the circuit - we can confirm flow against the published curves before you commit. This unit is specified with the 5 um element (code W); choose 5 um where downstream equipment needs finer particulate removal, or the 40 um standard grade for general protection. The differential-pressure drain is the default: it bleeds condensate automatically in response to the pressure differential, with no manual draining routine. The regulator here is the low-pressure type (code L), intended for circuits set below standard regulator ranges - ask us to confirm the exact adjustment range for your setpoint. The round external gauge is scaled in psi; square embedded gauges and MPa or bar scales are the alternatives. Thread is G (BSPP) on this code; PT is the standard offering and NPT is also an order option. A bracket is included. Flow is published as curves, not a single rating, so please ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so there is no one rated flow number we can quote. Tell us your port size and application demand and we will confirm the flow and full datasheet figures for the GC600 on request before you order.

L marks the low-pressure regulator type, intended for circuits set below standard regulator ranges - the exact adjustment range is not published, so ask us to confirm it against your setpoint. W marks the 5 um filter element, one grade finer than the 40 um standard. The code also decodes the round psi gauge, the fitted reverse/check valve, the differential-pressure drain and the G1 (1 in) G-thread port.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600C25LC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C25LC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.