The AirTAC GFR200-06 AirTAC Filter Regulator 1/8in PT Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 200 unit has a PT 1/8 in port, a 40 um standard filter element, and a manual drain you operate by hand to empty the polycarbonate bowl. It is the standard regulator type with an adjustment range of 0.05-0.9 MPa (7-130 psi), a round external gauge reading in psi, and a reverse/check valve fitted to hold downstream pressure. A mounting bracket is included.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drains, an optional 5 um element (code W), gauge scales in MPa, psi or bar, and G or NPT thread options. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200-06 AirTAC Filter Regulator 1/8in PT Manual Drain |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
A single-station bench press with a small air cylinder needs clean, dried air and a set working pressure for consistent forming or staking. The GFR200-06 filters water and debris from the shop line, regulates the cylinder pressure, and its check valve holds the setting if supply pressure dips mid-cycle.
A lab bench running small pneumatic actuators for sample handling requires particulate-free air at a stable, low pressure. The 40 um element protects the actuators, the manual drain lets staff bleed accumulated water after each shift, and the psi gauge gives a clear local reading at the point of use.
A carton taping or sealing head on a packaging line uses short air bursts at a fixed pressure. This filter regulator cleans the supply, holds the set pressure for repeatable seal quality, and the included bracket lets it mount directly on the machine frame close to the point of use.
Start with the port step: size 200 with a 1/8 in PT port suits compact circuits, and the GFR series steps up through 300, 400 and 600 for larger ports and higher flow demand. Because flow is published as curves rather than one rated number, send us your application details and we will confirm sizing against the datasheet before you order. For the drain, this unit is manual, which suits installations where an operator can bleed the bowl on a schedule; automatic and differential-pressure drains are available elsewhere in the series if unattended drainage is preferred. The 40 um element is the standard grade, with a 5 um option (W) when finer filtration is needed. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are alternatives. Thread is PT as standard, with G and NPT available to order, and a mounting bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the datasheet flow curve and sizing for the GFR200-06 on request before you order.
The M in the code GFR20006MC2K means the polycarbonate bowl is emptied by hand, which suits stations an operator visits regularly. The GFR series also offers automatic (A) and differential-pressure (blank) drains that remove condensate without operator action, if your installation is unattended.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.