AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain

The AirTAC GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$46.69 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain

The AirTAC GFR200-06 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is the size 200 unit with a G1/8 (BSPP) port, a fine 5 um filter element (code W, versus the 40 um standard), a manual drain on the polycarbonate bowl, and the low-pressure (L) regulator type for circuits set well below standard line pressure. It is fitted with an external round gauge scaled in psi and a reverse/check valve (code K), and includes a mounting bracket.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drain, 40 um or 5 um filtration, gauge style and scale, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the figures for your application on request.

GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain Technical Specifications

ModelGFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain
SeriesGFR200 filter regulator
Port sizePT1/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain

GFR200G-series filter regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/8" · 5 µm
One size upGFR300
Add lubricationGFC200-06 (two-unit set)

Where the GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain Is Used

precision_manufacturing

Pneumatic clamping on machining fixtures

On a CNC fixture circuit where workpieces must be held at a deliberately low, gentle set pressure, the low-pressure regulator type lets the setter dial in the clamp force, while the 5 um element keeps fine contamination out of the clamp cylinders and the check valve holds the setting if upstream supply dips.

science

Instrument air for laboratory and test rigs

Bench-top test rigs and analytical instruments fed from a shop-air header need clean, steady air at reduced pressure. The 5 um grade protects sensitive pneumatic controls, the psi-scaled round gauge gives a direct reading at the rig, and the G1/8 port suits compact manifold plumbing.

air

Air-sparing and cooling jets on packaging lines

Low-pressure air knives and sparing jets on a packaging or filling line need filtered air regulated well below main line pressure. The manual drain lets an operator bleed the bowl during changeover, and the included bracket mounts the unit directly on the machine frame next to the jets.

Is the GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain the Right Unit?

Start with the port step: size 200 carries the 1/8 in port in this code, and larger sizes (300/400/600) step up to bigger ports and higher flow capacity, so match the size to the air demand of the circuit rather than the fitting alone. Choose the drain to suit access: manual drain (as here) needs an operator to bleed the bowl, automatic drain handles it unattended, and differential-pressure drain is the catalogue default. Pick 5 um filtration when downstream valves, cylinders or instruments need finer air than the 40 um standard element delivers. The round gauge here is scaled in psi; square embedded gauges and MPa or bar scales are also available. Thread options are PT (standard), G (this unit) and NPT, all orderable. Note the L code: this is the low-pressure regulator type, intended for circuits set below standard regulator ranges - its exact adjustment range is not published, so confirm it with us before ordering. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before you buy.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Send us your application details and we will confirm the relevant flow-curve figures from the datasheet on request before you order.

The L code marks the low-pressure regulator type, intended for circuits set below standard regulator ranges; its exact adjustment range is not published, so confirm it with us on request. The M code means the polycarbonate bowl has a manual drain: an operator opens it to bleed collected water, unlike the automatic or differential-pressure drain options available in the same series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200-06 AirTAC Filter Regulator G1/8, 5 um, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20006MLC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.