The AirTAC GFR200-06 AirTAC Filter Regulator NPT1/8 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06 is a filter regulator: it removes water and particulate from compressed air and sets downstream pressure in one compact body. This 200-size unit is fitted with a 1/8 in NPT port, a manual drain bowl in polycarbonate, a 5 um filter element (the finer of the two catalogue grades), a standard regulator with a 0.05-0.9 MPa (7-130 psi) adjustment range, and an embedded square gauge scaled in psi. No mounting bracket and no reverse/check valve are fitted in this configuration.
This is a genuine AirTAC part. The GFR filter-regulator family is published in sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, manual, automatic or differential-pressure drains, 40 um or 5 um elements, and gauge choices. Flow is published as curves rather than a single rated figure, so we confirm the datasheet figures for your application on request.
| Model | GFR200-06 AirTAC Filter Regulator NPT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Mounted at the drop of a small bench press or clamping fixture, it dries and filters the air to 5 um and holds a set working pressure for consistent clamping force.
Feeding analytical or test-bench instruments that need clean, moisture-reduced air at a stable, low setpoint, with the 5 um element protecting sensitive internals.
Installed on the air inlet of a packaging or labelling machine, combining water and particle removal with a regulated supply for its cylinders and actuators.
Size the GFR by port and expected flow: this 200 size with a 1/8 in NPT port suits the smallest branch lines; step up to 300/400/600 where larger ports and higher flow are needed. The 5 um element in this unit is the finer choice for sensitive downstream equipment; the standard grade is 40 um. The manual drain fitted here means an operator opens the bowl drain periodically - choose automatic or differential-pressure drain if the unit is hard to reach. The square gauge reads in psi; MPa and bar scales and an external round gauge are alternatives. PT is the standard thread, with G and NPT as order options; a mounting bracket can be specified.
Because catalogue flow is published as curves and not as a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and expected air demand and we will confirm the flow and datasheet figures for this exact model on request.
The M in the code means the bowl drain is opened by hand to expel collected water, which suits accessible mounting points with routine checks. If the unit will sit in a hard-to-reach spot, ask for the automatic or differential-pressure drain version of the same GFR200-06 instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.