The AirTAC GFR200-06 AirTAC Filter Regulator, PT1/8, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200-06 is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is the 200 size with 1/8 in PT ports, a manual drain bowl, the standard 40 um filter element, a low-pressure regulator type, and an embedded square gauge reading in psi. It is mounted without a bracket and has no reverse/check valve fitted.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, manual, automatic or differential-pressure drains, a 5 um element option (code W), and gauge scale choices. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR200-06 AirTAC Filter Regulator, PT1/8, Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds and regulates the clamping actuators on a jig or fixture where the workpiece requires a lower holding pressure than the main shop air line delivers, with the manual drain bled during shift checks.
Mounted at the air inlet of a cartoning or wrapping machine, cleaning the supply of water and grit and holding a reduced, stable pressure to the machine's pneumatic cylinders.
Conditioning and regulating air on a laboratory or QC test bench where instruments and small pneumatic tools need filtered air at a controlled low pressure, read locally on the psi gauge.
Start with the size and port: the 200 series with 1/8 in PT ports suits compact circuits, and stepping up to 300/400/600 increases both port size and flow capacity - match the step against the air demand of the circuit. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering. This unit is the low-pressure regulator type; confirm its adjustment range with us if your setpoint is critical. The manual drain means someone bleeds the bowl periodically - choose the automatic or differential-pressure drain option if the unit sits where regular draining is impractical. The 40 um element is standard; select the 5 um W option where finer filtration is needed. The embedded square gauge here reads psi; MPa and bar scales are available, and an external round gauge is optional. Thread is PT as standard, with G and NPT as orderable options, and a mounting bracket can be added if this no-bracket configuration does not suit your panel.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so there is no one figure we can honestly quote. Tell us your application and we will confirm the flow and datasheet figures for the GFR200-06 on request before you order.
The M in this code selects a manual drain: collected water is released by opening the drain by hand, so the bowl needs periodic attention. It is a simple, reliable choice on units that are checked regularly; if the unit is hard to reach, the automatic or differential-pressure drain variants are the better decode.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.