The AirTAC GFR200-06F2W AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06F2W is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure in one compact body. This 200-size unit has a PT1/8 (1/8 in) PT thread, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain on the PC bowl, and an embedded square gauge reading in psi. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of drain (differential-pressure, automatic or manual), 40 um or 5 um elements, gauge styles and scales, and G (BSPP) or NPT thread options. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR200-06F2W AirTAC Filter Regulator PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Conditioning the air feeding directional control valves on a packaging machine's pick-and-place station, keeping water and fine particles out of the valve while holding a set working pressure.
Supplying filtered, regulated air to the pneumatic clamps and tool-change cylinders on a CNC machining cell, where a stable set pressure keeps clamping repeatable.
Conditioning the air supply to a small paint-spray or glue application station, where the 5 um element helps keep moisture and debris out of the nozzle and the regulator holds the set working pressure.
Size and port: 200 is the smallest GFR size, with a PT1/8 (1/8 in) port - step up to 300, 400 or 600 for larger ports and higher flow. Drain: this unit uses the differential-pressure drain (the default); automatic (code A) and manual (code M) versions are catalogue options. Element: 5 um here (code W) versus the standard 40 um - choose 5 um where finer filtration matters. Gauge: the embedded square gauge on this unit reads in psi; external round gauges and MPa or bar scales are options. Thread is PT as standard, with G (BSPP) and NPT as order options, and a mounting bracket is included. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Send us your application details and we will confirm the flow and datasheet figures for this exact unit on request.
The W code on this unit selects the 5 um element, the finer of the two catalogue grades, which catches smaller particles than the standard 40 um element. Choose 5 um where downstream equipment is sensitive to fine contamination; 40 um suits general-purpose air prep. Both grades are catalogue options across the GFR range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.