The AirTAC GFR200-06L AirTAC Filter Regulator, NPT1/8, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR200-06L is an AirTAC filter regulator in the compact size 200 frame: a 40 um element removes water and particulate from the compressed air and a low-pressure regulator sets downstream pressure, all in one body. This configuration has 1/8 in NPT ports, a polycarbonate bowl with the differential-pressure drain (the default drain type), a round pressure gauge reading in bar, and is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part, supplied under the full code GFR20006LJC3T. The GFR series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, PT, G (BSPP) or NPT threads, manual, automatic or differential-pressure drains, 40 um standard or 5 um (code W) filtration, and embedded square or external round gauges with MPa, psi or bar scales. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR200-06L AirTAC Filter Regulator, NPT1/8, Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use conditioning on a spray finishing line: one body strips water and particles from the supply and holds the gun circuit at the lower pressure the finishing process calls for.
Feeding clean, regulated air to the small cylinders and actuators on packaging machinery, where the low-pressure regulator type suits circuits that run below standard line pressure.
Conditioning bench air for lab apparatus and pilot rigs that need particulate-free air regulated to a low, stable setting, with the bar-scale gauge giving a direct local readout.
The real choices in this code are: size 200 with 1/8 in NPT ports (step up to 300/400/600 when your flow demand outgrows the port); the low-pressure regulator type for circuits that run below standard line pressure; the 40 um standard element (5 um is available as code W); the differential-pressure drain; and the round gauge with bar scale. Thread is NPT here; PT is the AirTAC standard and G (BSPP) is also orderable. This unit is supplied without a mounting bracket; brackets are optional on the series.
Flow for this series is published as curves, not a single rated number, so send us your flow and pressure requirements and we will confirm the right size from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no one flow number we can honestly quote for this model. Tell us your flow and pressure requirements and we will confirm the sizing of GFR200-06L against your application from the datasheet on request.
It marks the low-pressure regulator type: the unit is built for circuits that run below standard line pressure. The exact adjustment range for the low-pressure type is not published in the material we hold, so we confirm it on request. The rest of the code decodes as: size 200, 1/8 in NPT ports, no mounting bracket, round gauge with bar scale, differential-pressure drain and 40 um filtration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.