The AirTAC GFR200-06LC1TK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200-06LC1TK is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size 200 unit carries a 1/8 in NPT port, the low-pressure regulator type, a 40 um standard filter element and a differential-pressure drain. The polycarbonate bowl allows a visual check of collected condensate, and the K code means a reverse (check) valve is fitted so the downstream setting is held if the supply drops. A round gauge with an MPa scale is fitted and the mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, and catalogue options including automatic or manual drains, a 5 um (W) filter element, embedded square or external round gauges with MPa, psi or bar scales, G (BSPP) or NPT threads in place of the PT standard, and a no-bracket (J) variant. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR200-06LC1TK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Filtered, regulated low-pressure air to small cylinders and clamps on packaging and labelling heads, with the fitted check valve holding the downstream setting if the main supply dips.
Conditioning the air feed to spray guns and low-pressure coating points on a finishing line: the 40 um element removes water and pipe scale ahead of the regulator so moisture does not spoil the finish.
Supplying pilot and actuation air to diverters, stops and gate cylinders on sorting and conveyor lines, with the round MPa gauge giving operators a visible setpoint at the panel.
Start with size and port: 200 is the smallest GFR frame and the 06 code gives a 1/8 in NPT port - step up to 300, 400 or 600 for larger ports and more flow. This unit uses the differential-pressure drain as standard; automatic (A) and manual (M) drains are catalogue options. The 40 um element is standard and the W code selects the finer 5 um grade. The C1 gauge code here means a round gauge with an MPa scale; an embedded square gauge, or psi or bar scales, are alternatives. The T in the code selects NPT thread - G (BSPP) is available and PT is the standard thread. The bracket is included; the J variant deletes it. Flow is published as curves, not a single rated figure, so send us your pressure and flow requirements and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and required flow and we will confirm the sizing from the datasheet on request.
L designates the low-pressure type regulator. The exact adjustment range for this low-pressure variant is not published in the catalogue sheet, so we confirm it on request. The rest of the code reads: 200 = size, 06 = 1/8 in NPT port, C1 = round gauge with MPa scale, T = NPT thread, K = reverse (check) valve fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.