The AirTAC GFR200-06T AirTAC Filter Regulator 1/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06T is a compact 200-size filter regulator that removes water and particulate from compressed air and holds downstream pressure steady in a single body. This configuration has a 1/8 in NPT port, a manual drain bowl in polycarbonate, a 40 um standard filter element, and a round gauge reading in psi, so one unit both cleans the air and lets you set and watch the working pressure at the point of use.
This is a genuine AirTAC part. The GFR range spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um filtration, and gauge options. Max inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR200-06T AirTAC Filter Regulator 1/8 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds and regulates the air to a small bench-mounted pneumatic press or clamping fixture, giving the operator a clean supply and a locally set, visible clamping pressure on the psi gauge.
Sits at the air inlet of a cartoning or labelling machine, dropping supply pressure to the level the machine's cylinders and actuators were designed for while keeping water and debris out of the valves.
Conditions the compressed air feeding lab benches, sample-handling actuators and small test rigs, where a compact 1/8 in NPT unit with manual drain and a clear psi readout keeps the setup simple.
Start with the port step: the 200 size takes 1/8 in ports, and larger sizes (300/400/600) carry bigger ports and more flow, so match the size to the air demand of the circuit. This unit has a manual drain, which suits installations where an operator can bleed the bowl routinely; choose automatic or differential-pressure drain codes if the unit will sit unattended. The 40 um element is the standard grade for general pneumatic supply; specify the W code if you need the 5 um option. The round psi gauge is fitted here, with square embedded gauges and MPa or bar scales available as alternatives. Thread is NPT on this code; PT is the standard thread and G (BSPP) is also a catalogue option. A mounting bracket is included. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a l/min or SCFM number here. Tell us your application and we will confirm the sizing figures from the datasheet on request before you order.
The M in the code GFR200-06MC2T specifies a manual drain bowl, which an operator empties by hand at intervals. If the unit will be installed where nobody can bleed it regularly, ask for the automatic (A) or differential-pressure (blank) drain variant of the same 200-size regulator instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.