The AirTAC GFR200-06T AirTAC Filter Regulator 1/8 in NPT 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06T is a filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This unit is built for 1/8 in NPT ports, filters to 5 um (the finer of the two catalogue grades), drains by differential pressure, and carries an embedded square gauge reading in MPa. The bowl is polycarbonate, standard for the 200 size, and no mounting bracket is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family runs from size 200 to 600 with larger ports and capacity on the bigger frames, and the catalogue options include manual or automatic drains, a 40 um standard element, external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm the figures from the datasheet for your application.
| Model | GFR200-06T AirTAC Filter Regulator 1/8 in NPT 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeding clamp cylinders on a machining fixture: the 5 um element keeps downstream spool valves clean while the regulator holds a steady clamp pressure through the cycle.
Point-of-use conditioning ahead of bench instruments and air-operated lab equipment, where fine 5 um filtration and an adjustable, gauge-backed pressure setting matter.
Supplying diverters and stop gates on a packaging conveyor, with the square MPa gauge letting operators check the set pressure at a glance.
Choose the size and port against the flow your line needs: this 200 unit takes 1/8 in NPT, while the 300, 400 and 600 frames step up in port and capacity. The 5 um element (code W) suits air that feeds sensitive valves or instruments; the 40 um standard grade is the catalogue choice for general cylinder supply. Drain is differential-pressure on this unit, with automatic and manual drains orderable. The square MPa gauge is fitted; psi or bar scales and an external round gauge are options. NPT is the thread here; PT and G are catalogue alternatives, and a mounting bracket can be ordered. Flow is published as curves, not a single rating, so send us your demand and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR200 as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the right size from the datasheet on request.
The 5 um element (code W) is the finer of the two catalogue grades and suits air feeding valves or instruments; the 40 um standard element is the catalogue choice for general cylinder supply. The differential-pressure drain is the default; automatic and manual drains are orderable alternatives if your usage pattern calls for them.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.