The AirTAC GFR200-06T AirTAC Filter Regulator 1/8 in NPT Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06T is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in a single body. This size 200 unit has a 1/8 in NPT port, a polycarbonate bowl with manual drain, a 40 um filter element, an embedded square gauge scaled in bar, and no mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the regulating range is 0.05-0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include automatic or differential-pressure drains, a 5 um element (code W), G or NPT threads, gauge scales in MPa, psi or bar, and mounting brackets. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR200-06T AirTAC Filter Regulator 1/8 in NPT Manual Drain |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use air prep for a packaging machine's pneumatic sealers: water and scale knocked out of the shop air line while the regulator holds a steady setpoint for consistent cylinder action.
Feeding a compact machining cell's air clamps and tool actuators, where stable downstream pressure protects part holding and a manual drain suits a supervised shift.
Supplying diverters and stop gates on a sorting conveyor, where the 1/8 in NPT port suits compact valve manifolds and the 40 um element keeps debris out of the valves.
Choose the size and port against the air your machine actually uses: GFR200 with a 1/8 in NPT port is the compact step in the range, and larger sizes move more air. Pick the drain to match attendance: manual (this unit) needs someone to open the drain, automatic drains on their own, and differential-pressure drains when the element loads up. The standard element is 40 um; specify code W for 5 um where finer filtration matters. Gauge scale is selectable (MPa, psi or bar - this unit is bar), and threads can be ordered in PT (standard), G or NPT. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not a single rated figure, so we do not quote a number here. Tell us your line pressure, setpoint and the air your equipment uses, and we will confirm the sizing from the datasheet on request.
This unit has a manual drain: someone opens the bowl drain to release collected water. Choose manual for supervised installations with regular checks; choose the automatic or differential-pressure drain option where the unit runs unattended or you want draining handled without a routine.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.