AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain

The AirTAC GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$29.78 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain

The AirTAC GFR200-08 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is the size 200 unit with a 1/4 in NPT port, a manual drain bowl in polycarbonate, and the standard 40 um filter element. The manual drain means an operator opens the bowl drain to expel collected condensate, which suits installations visited during routine checks. With no gauge fitted, add a separate gauge if a visual pressure reading is wanted at the point of use. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.

This is a genuine AirTAC part. The GFR filter regulator family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options include 5 um filtration (code W), automatic or differential-pressure draining, an embedded square gauge or external round gauge in MPa, psi or bar scales, a reverse/check valve, and G (BSPP) or NPT threads in place of the PT standard. We confirm flow and datasheet figures on request, since flow is published as curves rather than a single rating.

GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain Technical Specifications

ModelGFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain
SeriesGFR200 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain

GFR200G-series filter regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/4" · 40 µm
One size upGFR300
Add lubricationGFC200-08 (two-unit set)

Where the GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain Is Used

precision_manufacturing

CNC machine tool air supply

Clean, regulated air feeding the tool-change and clamping circuits of a machining centre, with the manual drain emptied during daily operator checks.

settings_input_component

Packaging machine air preparation

Point-of-use conditioning for carton-sealing and wrapping equipment, where the regulator holds a steady setting for the machine's pneumatic actuators.

valve

Pneumatic valve actuation skid

Supplying filtered, pressure-controlled air to a bank of solenoid-operated process valves on a plant skid, with the bracket securing the unit to the panel.

Is the GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain the Right Unit?

Start with the port step: this unit is size 200 with a 1/4 in NPT port; larger sizes (300, 400, 600) step up to 3/8 in through 1 in, so match the size to the air demand of the circuit. Choose the drain to suit access: manual (this unit) for attended installations, automatic for unattended ones, or the differential-pressure default. The standard element is 40 um; specify 5 um (code W) where finer particulate removal is needed. If you want a pressure reading, select the embedded square gauge or the external round gauge and its scale (MPa, psi or bar). Thread is PT as standard; G (BSPP) and NPT are order options, and this unit is supplied with an NPT port. A bracket is included; J codes omit it. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a number. Tell us your application and required flow, and we will confirm sizing against the datasheet curves on request before you order.

The M in the code specifies a manual drain: condensate collected in the polycarbonate bowl is released by opening the drain by hand. It suits installations that are checked regularly. For unattended or hard-to-reach points, choose the automatic drain (code A) or the differential-pressure default instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200-08 AirTAC Filter Regulator, NPT 1/4, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.