The AirTAC GFR20006JC1TK AirTAC Filter Regulator, NPT 1/8 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006JC1TK is an AirTAC GFR200 filter regulator: a single body that removes water and particulate from compressed air and holds downstream pressure steady. This unit is threaded NPT 1/8 in, carries the standard 40 um filter element, drains condensate by differential pressure, and is fitted with a round pressure gauge reading in MPa. A reverse/check valve is built in, and the unit is supplied without a mounting bracket.
It is a genuine AirTAC part from the GFR series, which spans size 200 to 600 with port sizes from 1/8 in to 1 in, manual or automatic drain options, a 5 um element (code W), and psi or bar gauge scales. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing against your application before ordering.
| Model | GFR20006JC1TK AirTAC Filter Regulator, NPT 1/8 in |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use conditioning at a machining centre: filtered, regulated air feeding the tool changer, clamps and pneumatic circuits from the shop air line.
Supplying air cylinders on a carton-forming or sealing conveyor with clean, moisture-controlled air at a steady set pressure for consistent stroke timing.
Protecting directional control valves and actuators on an automated assembly station from water and particulate carryover upstream of the manifold.
The decodable choices on this family are the size and port (200 to 600, 1/8 in to 1 in - step up for higher flow), the drain type (differential-pressure as here, automatic with code A, or manual with code M), the filter grade (40 um standard, 5 um with code W), the gauge (round or square, scaled in MPa, psi or bar), the thread (PT standard, G or NPT to order) and whether a bracket is fitted. Regulation range on this unit is 0.15-0.9 MPa (20-130 psi).
Flow is published as curves, not a single rating, so ask us to confirm sizing against the application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
Flow for the GFR series is published as curves, not a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the correct size and flow from the AirTAC datasheet on request.
Condensate is discharged automatically when the pressure difference across the filter element reaches a set level, with no manual intervention. If you prefer a manual or fully automatic drain, codes M and A cover those options on GFR units.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.