The AirTAC GFR20006JF2G AirTAC Filter Regulator G1/8, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006JF2G is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in a single compact body. This GFR200 configuration has a G1/8 (1/8 in) port, 40 um standard filtration, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element is high enough, and a fitted embedded square gauge reading in psi. The standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit is supplied without a mounting bracket. The polycarbonate bowl suits non-freezing compressed-air service from -5 to 70 C.
This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, optional 5 um (code W) filtration, automatic or manual drains, alternative gauge scales, and G or NPT thread options to order. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR20006JF2G AirTAC Filter Regulator G1/8, 40 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds filtered, pressure-regulated air to the tool-clamp and chip-blow-off circuits of a small CNC lathe or mill, with the psi gauge letting the setter verify clamp pressure at the machine.
Conditions the air feeding cylinders and diverters on a carton-sealing or case-packing conveyor, keeping moisture and debris out of the valves while holding a stable setpoint for consistent stroke timing.
Supplies clean, regulated air to benchtop analytical or test instruments in a lab, where the 40 um element protects sensitive pneumatic controls and the square gauge gives a clear psi reading.
Start with the port and size step: this GFR200 unit has a G1/8 port, and the family steps up through GFR300, GFR400 and GFR600 to 1 in for higher air demand - match the size to your line's flow requirement rather than only the pipe thread. Choose the drain to suit access: differential-pressure (this unit) self-drains with pressure drop, automatic drains continuously, and manual suits attended installations. Filtration is 40 um standard here; specify 5 um (code W) where finer protection is needed. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are alternatives, and G or NPT threads are order options against the PT standard. Note the flow curve point honestly: AirTAC publishes flow as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and we will confirm the flow curve and correct sizing from the datasheet on request.
This configuration has a differential-pressure drain: condensate collected in the polycarbonate bowl is discharged automatically when the pressure drop across the filter element rises, with no operator action needed. If you prefer fully continuous draining or a manual drain valve, GFR200 variants with automatic (A) or manual (M) drains are available - ask us to quote the alternative code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.