The AirTAC GFR20006JF3TK AirTAC Filter Regulator NPT 1/8 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006JF3TK is a size-200 GFR-series filter regulator: it removes water and particulate from compressed air and sets downstream pressure in one compact body. This configuration is fitted with a 1/8 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, an embedded square gauge reading in bar, and a built-in reverse (check) valve that holds the downstream setting when upstream supply is lost. It is ordered without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range for this drain type is 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits the 200 size.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, a choice of 40 um or 5 um (W) filtration, differential-pressure, automatic or manual drains, and gauge or no-gauge variants. Flow figures for this series are published as curves rather than a single rated number, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR20006JF3TK AirTAC Filter Regulator NPT 1/8 in |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds clean, pressure-set air to the tool-change clamps and air-blast circuits of a small machining centre, with the check valve holding the clamp setting during a supply dip.
Conditions the air going to cylinders and grippers on a carton-forming or case-sealing conveyor, filtering out water and pipe scale before it reaches the valves.
A point-of-use filter regulator at an assembly or test bench, giving operators a locally adjusted, dried supply for air tools and small fixtures off the main header.
Start with the port and size step: the GFR200 with a 1/8 in NPT port is the entry size of the range, so match it against the air consumption of the machine or line it feeds - if your demand sits near the top of the 200-size curve, step up to GFR300 or GFR400 rather than oversizing the regulator setting. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order. The other decodable choices on this unit are already fixed: 40 um standard filtration (specify W for 5 um if finer filtering is needed), differential-pressure drain (choose automatic or manual codes if you prefer a different condensate handling method), square gauge in bar (round external gauges and MPa/psi scales are available), NPT thread (PT is the catalogue standard; G is also offered), check valve fitted, and no bracket. If you need a mounting bracket, order the bracket-included variant of the same size.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as performance curves, not as a single rated number, so we do not quote a l/min or SCFM figure here. Send us your application details and we will confirm the datasheet curve and correct size for your flow demand on request.
This unit's differential-pressure drain bleeds accumulated condensate from the bowl automatically as air flows through, with no operator attention. If your line has intermittent flow that may not clear the bowl, or you want positive manual control, the same GFR200 size is available with an automatic (A) or manual (M) drain code instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.