verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure

The AirTAC GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$35.76 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure

The GFR20006LF3T is an AirTAC GFR200-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration is the 200 size with a 1/8 in NPT port, the low-pressure regulator type, a 40 um standard filter element, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. A square pressure gauge with a bar scale is fitted so the set pressure is visible at a glance, and a mounting bracket is included for secure panel or wall fixing.

This is a genuine AirTAC part. The GFR family is published in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 5 um (code W) element option, gauge scale choices, and G or NPT thread options in addition to the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application.

GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure Technical Specifications

ModelGFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure
SeriesGFR200 filter regulator
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure

GFR200G-series filter regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/8" · 40 µm
One size upGFR300
Add lubricationGFC200-06 (two-unit set)

Where the GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure Is Used

tune

Low-pressure paint and coating lines

Spray booths and coating heads that run below conventional regulator bands need clean, gently regulated air. This low-pressure GFR filters water and particulate and holds the reduced pressure, with the bar-scale gauge showing the setpoint.

precision_manufacturing

Pneumatic clamping on small assembly fixtures

Bench-top clamping and hold-down fixtures need filtered air and a stable reduced pressure at the point of use. The 1/8 in NPT port suits compact drop lines, and the included bracket fixes the unit beside the fixture.

science

Laboratory and test-bench air supply

Test rigs and lab apparatus fed from a shop-air header need particulate- and water-free air at a controlled low pressure. The differential-pressure drain keeps condensate moving out without manual attention, and the square gauge gives a clear bar reading.

Is the GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure the Right Unit?

Start with the port step: this unit is the 200 size with a 1/8 in NPT port, so match it to the line size and the flow your circuit needs - larger GFR sizes step up in port and flow capacity. The low-pressure type here is intended for circuits that work below the standard regulator band; if your process runs at conventional shop-air pressures, a standard-type GFR may be the better fit. The 40 um element is the standard grade for general air preparation; specify the 5 um W-code element where finer filtration is required. Drain choice matters: the differential-pressure drain on this unit needs no operator attention, while automatic and manual drains are order options. The fitted square gauge reads in bar; MPa and psi scales are available. Thread is NPT here, with G and PT as catalogue options, and a mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure, set pressure and required flow, and we will confirm the datasheet curve and check the sizing for your application before you order.

The L in the code marks the low-pressure regulator type, intended for circuits that operate below the standard regulation band; the exact range for this variant is not published, so ask us to confirm it for your setpoint. The drain code is blank, which means the differential-pressure drain: condensate collected in the PC bowl is discharged automatically when the pressure drop across the 40 um element is high enough, with no manual draining needed.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR20006LF3T AirTAC Filter Regulator NPT1/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20006LF3T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.