The AirTAC GFR20006LJC2 AirTAC Filter Regulator PT 1/8 in Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006LJC2 is a compact filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size-200 unit has a PT 1/8 in port, the low-pressure regulator type, a 40 um standard filter element and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. It is fitted with an external round gauge scaled in psi, and no mounting bracket is included.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 40 um standard or 5 um (W) filter element, standard or low-pressure regulation, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR20006LJC2 AirTAC Filter Regulator PT 1/8 in Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Clean, regulated air for a small solenoid-valve manifold driving actuators on a packaging or assembly machine, with the round psi gauge giving operators a direct local pressure reading.
A low-pressure regulated air feed for bench-top test rigs, sample-prep stations or analytical instruments where the circuit operates below standard regulator ranges and needs water and particulate removed first.
Filtered, regulated air for light-duty clamps, air cylinders and jigs on a workbench or fixture, where the 1/8 in port matches compact tooling and the differential drain keeps condensate under control.
Start with the port and size: this unit is size 200 with a PT 1/8 in port, the smallest step in the GFR range, so check that the line size and the air demand of the downstream equipment suit the smallest frame before stepping up to 300, 400 or 600. The low-pressure regulator type in this code is intended for circuits that work below the standard regulator's range; the exact adjustment span for this variant is not published, so confirm it with us. Drain is differential-pressure by default here; choose automatic (A) or manual (M) codes if your installation needs a different condensate strategy. The 40 um element is the standard grade; specify W for 5 um where finer filtration is required. The round gauge in this code is scaled in psi; square embedded gauges and MPa or bar scales are alternatives. Thread is PT as standard, with G and NPT available as order options, and a bracket can be added if this no-bracket code does not suit your mounting.
Because AirTAC publishes flow only as curves and not as a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm sizing and the datasheet figures before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a flow number for this unit. Tell us your line size and the air demand of your equipment and we will confirm the sizing and datasheet figures for the GFR20006LJC2 on request before you order.
The L in the code marks the low-pressure regulator type, intended for circuits that operate below the standard regulator's range; the exact adjustment span for this variant is not published, so confirm it with us. The drain on this unit is the differential-pressure type: condensate collected in the PC bowl is discharged automatically when the pressure differential across the 40 um element is high enough, with no manual draining needed in normal service.
Genuine AirTAC parts produced by AirTAC factory.