verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure

The AirTAC GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$45.65 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure

The AirTAC GFR20006LJF2TK is a size 200 filter regulator that removes water and particulate from compressed air and reduces pressure to the level your circuit needs, in a single compact body. This configuration is the low-pressure type, built for circuits that run at reduced set pressures, with a 40 um standard filter element, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, an embedded square gauge reading in psi, and a built-in reverse (check) valve that holds your downstream setting if upstream supply is interrupted. It carries no bracket, so plan for direct line or your own bracket mounting. The polycarbonate bowl is rated for the same working envelope as the unit: maximum inlet pressure 1.0 MPa (145 psi) and a non-freezing temperature range of -5 to 70 C.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and each size can be ordered with manual or automatic drain, a 5 um (W) element, different gauge scales, G or NPT thread, and with or without a bracket. Flow for this series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures against your application before you order.

GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure Technical Specifications

ModelGFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure
SeriesGFR200 filter regulator
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure

GFR200G-series filter regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/8" · 40 µm
One size upGFR300
Add lubricationGFC200-06 (two-unit set)

Where the GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure Is Used

settings_input_component

Low-pressure clamp circuits on packaging machinery

Feeds filtered, regulated air to the low-pressure clamping and holding circuits of a packaging line, where the low-pressure type keeps the supply matched to circuits designed to run below full line pressure.

science

Air preparation for laboratory and instrumentation panels

Serves as the first-stage supply unit for analytical instruments and test panels that need water and particulate stripped from compressed air, with the check valve protecting the set pressure against upstream dips.

precision_manufacturing

Point-of-use supply for a small CNC tooling station

Mounted at the point of use on a compact machining or assembly station, it conditions the air feeding valves and actuators while the square psi gauge gives the operator a direct read of the working pressure.

Is the GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure the Right Unit?

Start with the port and size step: this unit is size 200 with a 1/8 in NPT port, the smallest step in the GFR range, so size up to 300/400/600 if your line port or air demand is larger. Because flow is published as curves and not a single rating, send us your application conditions and we will confirm sizing from the datasheet before you order. Other decodable choices: drain type (this unit uses the differential-pressure drain; automatic A and manual M versions exist), filter grade (40 um standard here, 5 um with the W code for finer filtration), gauge scale (this one reads psi; MPa and bar scales are available), thread (PT is the standard; G and NPT are catalogue options, and this unit is ordered in NPT), and bracket (J codes omit the bracket, as here). Note that the low-pressure type (L) has its own regulation characteristics; its exact range is not published in our sheet, so confirm it with us for your set pressure.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Send us your line pressure, port size and air demand, and we will confirm the datasheet curve figures against your application before you order.

L marks the low-pressure regulator type, intended for circuits running at reduced set pressures (confirm the exact range with us, as it is not published on our sheet). K means a reverse (check) valve is fitted, so downstream pressure is held if the upstream supply drops. This unit has no A or M drain code, so it uses the differential-pressure drain, which expels collected condensate automatically as air flows through, with no manual draining routine.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR20006LJF2TK AirTAC Filter Regulator NPT1/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20006LJF2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.