The AirTAC GFR20006LJNWT AirTAC Filter Regulator, NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006LJNWT is an AirTAC GFR-series filter regulator: water and particulate removal plus downstream pressure regulation combined in a single body. This size 200 configuration carries a 1/8 in NPT port, a 5 um filter element (code W), a differential-pressure drain and the low-pressure regulator type. It is supplied without a gauge and without a mounting bracket.
It is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um filtration, gauge options and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures against your application.
| Model | GFR20006LJNWT AirTAC Filter Regulator, NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Filtered, regulated supply air to the clamp cylinders on a machining fixture, with the 5 um element helping keep contaminants out of the clamping valves.
Conditioning the air feeding the directional valves and small actuators on a carton-sealing or labelling line, with the differential-pressure drain handling condensate.
Clean, regulated air to pilot-scale apparatus and test benches where a compact 1/8 in connection and fine 5 um filtration suit sensitive downstream equipment.
Size steps from 200 to 600 as port and flow demand grow; this unit is the size 200 entry with a 1/8 in NPT port. Drain may be differential-pressure (standard here), automatic or manual. Filtration is 40 um standard or 5 um with the W code, as fitted here. Gauge and scale, PT versus G or NPT thread and a mounting bracket are all order-time choices; this configuration carries none of the three. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and we will confirm the flow figures from the datasheet on request.
The L in the code marks the low-pressure regulator variant of the GFR filter regulator. The exact regulation range for this low-pressure configuration is not published in our data, so please confirm the set-point you need with us before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.