The AirTAC GFR20006MF2K AirTAC Filter Regulator PT1/8, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006MF2K is an AirTAC GFR200 filter regulator: one compact body that removes water and particulate from compressed air and holds downstream pressure steady. This configuration is a 200-size unit with a PT1/8 (1/8 in) port, a 40 um standard filter element, and a manual drain you open by hand to expel collected condensate. The embedded square gauge reads in psi, and a reverse/check valve is fitted so the set pressure is held if upstream supply is interrupted.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, drain choices (manual, automatic or differential-pressure), a 5 um element option (code W), gauge scale choices, and G or NPT thread options. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR20006MF2K AirTAC Filter Regulator PT1/8, 40 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feed a clean, regulated air supply to a machining centre's pneumatic tool clamps and chip-ejection cylinders, with the psi gauge letting operators verify set pressure at a glance.
Condition the air feeding conveyor stoppers and carton-sealing cylinders on a packaging line, with the manual drain emptied during shift-change housekeeping.
Serve as the conditioning and regulation point where a branch line leaves the main header in a factory, protecting downstream valves and cylinders from water and pressure swings.
Size and port set the ceiling on flow: the 200 size with a PT1/8 port suits compact lines and point-of-use drops; step up to 300, 400 or 600 when the demand outgrows it. Drain type is a real choice: manual (this unit) is simple and low-cost but needs someone to open the bowl; automatic or differential-pressure drain suits unattended installations. The 40 um element is standard for general plant air; specify the 5 um W option where finer filtration matters. The square gauge here reads psi; MPa and bar scales are also available. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and a mounting bracket is included.
Because flow is published as curves and not a single rating, send us your air demand and line conditions and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR200 as curves, not as a single rated figure, so we do not quote a number. Tell us your air demand and line conditions and we will confirm the datasheet flow figures for this PT1/8 unit on request before you order.
The M in the code specifies a manual drain: condensate collects in the polycarbonate bowl and you open the drain by hand to release it. It is the straightforward choice for attended equipment; for installations nobody visits regularly, ask about the automatic or differential-pressure drain variants of the same GFR200 body.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.