The AirTAC GFR20006MF2WGK AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MF2WGK is a GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration has a G1/8 (1/8 in) port, a 5 um filter element (the 40 um standard element is also available in the series), a manual drain on the PC bowl, an embedded square gauge with psi scale, and a built-in reverse (check) valve. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of G, NPT or PT thread, manual, automatic or differential-pressure drains, 40 um or 5 um filtration, and gauge or no-gauge options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR20006MF2WGK AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use conditioning for actuated process and directional control valves: the 5 um element keeps grit and condensed water out of valve seats, while the regulator holds a steady set pressure and the check valve holds the line if upstream air is lost.
Feeding tool-clamp cylinders, chip doors and air-blast nozzles on a machining centre, where the manual drain suits a scheduled shift-start check and the square psi gauge lets an operator verify set pressure at a glance.
Conditioning the air supply to carton-sealers, pick-and-place cylinders and stopper gates on a packaging conveyor, where clean, regulated air keeps cycle behaviour consistent and the check valve prevents backflow between stations.
Size and port step up with flow demand: this unit is size 200 with a G1/8 port, and the series runs through 300, 400 and 600 with larger ports. Choose the drain to match your maintenance routine: manual (this unit) drains on schedule, automatic drains hands-free, and differential-pressure drains as the element loads up. Filter grade is 40 um standard or 5 um (code W, this unit) for finer protection. Gauge scale is MPa, psi or bar, thread is PT standard with G and NPT as order options, and a mounting bracket is included with this unit. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so there is no one l/min or SCFM number we can quote for this unit. Tell us your working pressure and air demand and we will confirm the flow figures from the datasheet for your application before you order.
The M in the code specifies a manual drain: condensate collected in the PC bowl is released when an operator opens the drain, which suits lines inspected on a fixed schedule. If you cannot guarantee regular checks, the same GFR200 body is available with an automatic drain or the default differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.