The AirTAC GFR20006MJC2WK AirTAC Filter Regulator 1/8 in, 5 um, Manual is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MJC2WK is a 200-size filter regulator that removes water and particulate from compressed air and holds downstream pressure steady in one compact body. This configuration is built for fine air: the 5 um element (code W) captures finer contamination than the standard 40 um grade, the manual drain lets an operator bleed accumulated condensate from the PC bowl on a chosen schedule, and the fitted check valve (code K) holds the downstream setting if upstream supply is interrupted. An external round gauge with a psi scale is included so the regulated pressure is visible at the unit, and the regulator is the standard type with a 0.05-0.9 MPa (7-130 psi) adjustment range. Porting is PT1/8 (1/8 in) with PT thread as standard.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with a choice of drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT as options) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR20006MJC2WK AirTAC Filter Regulator 1/8 in, 5 um, Manual |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
On a benchtop milling or drilling fixture, air clamps need clean air and a pressure setting that does not drift. The 5 um element protects the clamp valve seats from fine particulate, the regulator holds the clamping pressure, and the check valve keeps the clamp from releasing if shop air dips. The 1/8 in ports suit the compact manifold typical of fixture panels.
Bench-top test rigs and analytical instruments fed from a shop-air drop need fine filtration and a stable, visible setpoint. This unit's 5 um element, psi round gauge and steady regulation make it a compact conditioning point right at the instrument, with manual draining done as part of the bench routine.
Small packaging and labelling machines use compact valve islands fed from a single 1/8 in drop. This filter regulator conditions that drop: the 5 um grade guards the island's internal clearances, the psi gauge gives operators a visible setpoint, and the check valve holds the circuit's pressure during brief supply interruptions so the machine does not fault out.
Start with the port step: the 200 size with 1/8 in ports suits compact supply drops, while larger GFR sizes (300/400/600) carry bigger ports for higher-demand lines - match the port to the flow your circuit needs. This unit carries the 5 um element (code W); choose it where downstream valves, cylinders or instruments need finer filtration than the standard 40 um grade, and note the finer element loads faster and needs more frequent manual draining. The manual drain means someone opens the bowl drain periodically - if the installation is unattended, consider an automatic-drain variant. The round psi gauge suits US-style readouts (MPa and bar scales are available on other variants), and the fitted check valve is worth specifying whenever backflow through the regulator would be a problem. PT thread is standard; G (BSPP) and NPT are order options, and this code specifies no mounting bracket.
Flow for this series is published as curves, not a single rated number, so we do not quote a rated flow figure. Send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow number for this unit. Tell us your application - supply pressure, set pressure and the air demand of the equipment downstream - and we will confirm the sizing against the datasheet on request before you order.
The M in the code means the PC bowl is drained by hand: an operator opens the drain to release accumulated water. It suits attended installations where draining can be part of a routine, and it pairs with the widest regulator adjustment range (0.05-0.9 MPa / 7-130 psi). If the unit will sit unattended, ask us about automatic-drain or differential-pressure-drain variants instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.