The AirTAC GFR20006MLF2WG AirTAC 5 um Filter Regulator G1/8 is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MLF2WG is a filter regulator: a 5 um filter element and a pressure regulator combined in one body, so the compressed air is cleaned and its pressure set in a single unit. This configuration has a G1/8 (1/8 in) port, a manual drain on the polycarbonate bowl, the low-pressure regulator type, an embedded square gauge scaled in psi, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
It is a genuine AirTAC part from the GFR series, which covers sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um standard or 5 um (W) filtration, gauge scale options, and G or NPT threads alongside the PT standard. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application.
| Model | GFR20006MLF2WG AirTAC 5 um Filter Regulator G1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
On a packaging machine, this unit feeds a glue or coating head: the 5 um element keeps particulate and water out of the applicator, the low-pressure regulator type suits a low set pressure, and the manual drain is emptied during the end-of-shift check.
Inside lab and analytical equipment, small pneumatic actuators and valves need clean air at a modest, stable pressure. The compact 200 size with a 1/8 in port, 5 um filtration and a psi-scaled square gauge fits a low-pressure instrument air circuit.
For a pneumatic clamp circuit that works at a lower set pressure than the main shop air, this filter regulator cleans the supply with its 5 um element and sets the clamp pressure, with the manual drain serviced as part of the maintenance round.
The main choice is the size and port step, matched to the flow your line needs: 200 is the smallest of the four GFR sizes (200/300/400/600), here with a 1/8 in port. This unit carries the W-grade 5 um element instead of the standard 40 um, a manual drain you operate by hand rather than an automatic or differential-pressure drain, a square gauge scaled in psi, and the low-pressure regulator type - confirm the set range you need with us. The thread here is G (BSPP); PT is the standard and NPT is also a catalogue option, and a mounting bracket is included. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and sizing from the datasheet before you order.
This unit has a manual drain: condensate collected in the polycarbonate bowl is released by hand. Choose manual where a maintenance round already passes the unit; choose the automatic or differential-pressure drain option where the unit is hard to reach. Note the filter grade here is 5 um (code W) instead of the 40 um standard.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.