The AirTAC GFR20006MLJF2W AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006MLJF2W is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is built around 1/8 in PT ports, a 5 um filter element (the finer of the two catalogue grades), a manual drain for the polycarbonate bowl, a low-pressure regulator type, and an embedded square gauge scaled in psi. No mounting bracket is fitted, so plan your installation accordingly.
This is a genuine AirTAC part from the GFR200 size in the G-series range, which spans sizes 200 through 600 with port options from 1/8 in to 1 in and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR20006MLJF2W AirTAC Filter Regulator PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds filtered, regulated low-pressure air to the solenoid valves and pilot circuits of a packaging line's control panel, with the psi gauge giving operators a local pressure readout at the panel.
Conditions the air feeding lab testers and calibration benches that need clean, finely filtered air at a stable low pressure, with the 5 um element protecting sensitive instrument internals.
Sits at a workbench drop to filter and regulate the air feeding hand-held pneumatic screwdrivers and small cylinders, with manual drain suiting stations that are serviced each shift.
Start with the port step: the 200 size with 1/8 in PT ports suits compact circuits, and larger sizes (300/400/600) carry bigger ports and more flow - match the step to your demand rather than upsizing blindly. This unit has the 5 um element (code W); the standard grade is 40 um, so choose 5 um where downstream equipment needs finer filtration. Drain is manual here, meaning someone drains the bowl periodically; automatic or differential-pressure drains are available on other variants if you cannot schedule that. The square gauge is scaled in psi, with MPa or bar scales and an external round gauge available as options. Thread is PT as standard, with G and NPT offered as catalogue options. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and we will confirm the datasheet flow figures and check the sizing against your demand before you order.
The M in the code selects a manual drain: accumulated condensate in the polycarbonate bowl must be drained by hand at intervals you set. If your installation cannot be serviced regularly, ask about the automatic or differential-pressure drain variants of the same GFR200 unit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.