The AirTAC GFR20006MLJF2WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MLJF2WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This 200-size unit is fitted with a 1/8 in NPT port, a fine 5 um filter element (the W grade, versus the standard 40 um), a manual drain on the PC bowl, and a low-pressure regulator type. The embedded square gauge is fitted and reads in psi, so the set pressure is visible at a glance. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series is available in 200, 300, 400 and 600 sizes with a choice of PT, G or NPT threads, manual, automatic or differential-pressure drains, 40 um or 5 um elements, standard or low-pressure regulator types, gauge scales in MPa, psi or bar, and an optional mounting bracket. Flow is published as curves rather than a single rating, so ask us to confirm the flow and datasheet figures for your application before ordering.
| Model | GFR20006MLJF2WT AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds clean, low-pressure air to small pneumatic grippers and cylinders, with the 5 um element protecting fine sealing surfaces and the psi gauge letting the technician set and verify the circuit pressure.
Supplies filtered, regulated air to air-nozzle blow-off points that clear dust and stray film from cartons, with the manual drain letting the operator bleed accumulated water at shift start.
Conditions the air feeding clamp cylinders on a fixture, filtering water and chips-carried moisture out of the supply while the regulator holds the clamping pressure steady across the cycle.
Start with the port step: this unit is 200 size with a 1/8 in NPT thread, so check it against your line size and the flow your circuit needs - larger sizes (300/400/600) carry bigger ports and more flow. The 5 um element (code W) suits air that feeds sensitive components; choose 40 um for general-purpose protection. The manual drain means someone bleeds the bowl on a routine - pick automatic or differential-pressure drain if the unit sits where regular draining is awkward. The low-pressure regulator type is intended for circuits set at low pressure; the exact regulation range for this type is not published, so confirm it with us. Gauge scale here is psi; MPa and bar scales are order options. PT is the standard thread and G or NPT are catalogue options ordered by suffix, and the J suffix means no mounting bracket is supplied.
One honest note on sizing: AirTAC publishes flow as curves, not a single rated figure, so we cannot quote a rated flow number. Send us your application details and we will confirm the flow and datasheet figures before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow number for this unit. Tell us your line size and the flow your circuit needs and we will confirm the flow and datasheet figures for the GFR20006MLJF2WT on request before you order.
The M in the code GFR20006MLJF2WT specifies a manual drain: accumulated water is bled from the PC bowl by hand on a routine. If the unit will be mounted where regular draining is impractical, the same 200-size filter regulator can be ordered with an automatic drain (code A) or a differential-pressure drain (blank) instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.